Extensions for automation
Modules
Mounting and dismounting function modules
163
EDK82EV903 DE/EN/FR 5.1
Note!
ƒ
Keep the blanking cover
and the FIF protection cover
so that you can
attach them again after you have dismounted the function module.
– Without the FIF cover
, the controller is inhibited.
– If no function module is plugged on, the controller without FIF cover
and
blanking cover
must not be commissioned (dangerous electrical voltage
at the FIF interface).
ƒ
When two function modules are operated, make sure that the two
terminals X3/28 (controller inhibit) of the interfaces FIF I and FIF II are
AND’ed internally and must be wired according to their
application.(