Commissioning
The most important codes for commissioning
T
EDK82MV222 DE/EN/FR 9.0
NOT
L
Code
IMPORTANT
Possible settings
No.
Selection
Lenze
Name
C0034*
uSEr
Setpoint
selection
range
Standard–I/O
(X3/8)
-12-
Observe the switch position
of the function module!
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10
V
Current 0 ... 20 mA
1
Current 4 ... 20 mA
Changing the direction of
rotation is only possible with
a digital signal.
2
Bipolar voltage -10 V ... +10 V
z
Minimum output
frequency (C0010) not
effective
z
Individual adjustment of
offset and gain
3
Current 4 ... 20 mA open-circuit
monitored
TRIP Sd5, if I < 4 mA
Changing the direction of
rotation is only possible with
a digital signal.
C0034*
(A)
uSEr
Setpoint
selection
range
Application I/O
Observe the jumper setting of
the function module!
1 X3/1U, X3/1I
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10
V
2 X3/2U, X3/2I
1
Bipolar voltage -10 V ... +10 V
Minimum output frequency
(C0010) not effective
2
Current 0 ... 20 mA
3
Current 4 ... 20 mA
Changing the direction of
rotation is only possible with
a digital signal.
4
Current 4 ... 20 mA open-circuit
monitored
Changing the direction of
rotation is only possible with
a digital signal.
TRIP Sd5 if I < 4 mA
C0037
JOG1
20.00 -650.00
{0.02
Hz}
650.00 JOG = fixed setpoint
Additional fixed setpoints
Ö
C0440
C0038
JOG2
30.00 -650.00
{0.02
Hz}
650.00
C0039
JOG3
40.00 -650.00
{0.02
Hz}
650.00
C0050*
uSEr
Output
frequency
(MCTRL1-NOU
T)
-650.00
{Hz}
650.00 Only display: Output
frequency without slip
compensation
C0087
Rated motor
speed
Æ
300
{1 rpm}
16000
Æ
Depending on the controller