Commissioning
The most important codes for commissioning
EDK82MV222 DE/EN/FR 9.0
L
NOS
Code
IMPORTANT
Possible settings
No.
Selection
Lenze
Name
C0013
uSEr
Deceleration
time main
setpoint
5.00 0.00
{0.02
s}
1300.00 Reference: frequency change
C0011 ... 0 Hz
z
Additional setpoint
Ö
C0221
z
Deceleration times can be
activated via digital
signals
Ö
C0103
C0014
Operating
mode
2
2
V/f characteristic control V ~ f
(Linear characteristic with constant
V
min
boost)
z
Commissioning without
motor parameter
identification possible
z
Benefit of identification
with C0148:
– Improved smooth
running at low speed
– V/f rated frequency
(C0015) and slip
(C0021) are calculated
and stored. They do not
have to be entered
3
V/f characteristic control V ~ f
2
(Square-law characteristic with
constant V
min
boost)
4
Vector control
For initial selection enter
the motor data and identify
the motor parameters with
C0148
Otherwise commissioning
is not possible
5
Sensorless torque control with
speed limitation
z
Torque setpoint via C0412/6
z
Speed limitation via setpoint 1
(NSET1-N1), if C0412/1 is
assigned, if not via max.
frequency (C0011)
C0015
uSEr
V/f rated
frequency
50.00 7.50
{0.02
Hz}
960.00
z
C0015 is calculated and
stored under C0148 when
the motor parameters are
identified
z
Settings applies to all
mains voltages permitted
C0016
uSEr
V
min
boost
Æ
0.00
{0.01
%}
40.00
Æ
Depending on the controller
Setting applies to all mains
voltages permitted