T
Commissioning
The most important codes for commissioning
EDK82MV222 DE/EN/FR 9.0
L
NOO
Code
IMPORTANT
Possible settings
No.
Selection
Lenze
Name
C0002*
uSEr
(cont.)
Saving of own
settings
9
PAR1
Ö
Own settings
You can save your own basic
settings for a controller (e.g.
machine delivery status):
1. Ensure that parameter set
1 is active
2. Controller inhibit
3. Set C0003 = 3,
acknowledge with
4. Set C0002 = 9,
acknowledge with
, to
save your own basic
settings
5. Set C0003 = 1,
acknowledge with
6. Enable the controller.
C0002*
uSEr
(cont.)
Loading/copyi
ng of your
own basic
settings
Using this function, PAR1 can
be copied to parameter sets
PAR2 ... PAR4
5
Own settings
Ö
PAR1
Restorage of own basic
setting in the selected
parameter set
6
Own settings
Ö
PAR2
7
Own settings
Ö
PAR3
8
Own settings
Ö
PAR4
C0003*
Non-volatile
parameter
saving
1
0
Parameter not saved in EEPROM
Data loss after mains
disconnection
1
Parameter always saved in
EEPROM
z
Active after every mains
connection
z
Cyclic parameter changes
via bus module are not
allowed.
3
Own settings saved in EEPROM
Subsequently save parameter
set 1 as own basic setting
with C0002 = 9