5 The connections
Fig. 10: The connections of the LZV200
5.1 Power supply: terminals U,V
The LZV200 is connected to the transformer TR150 via two cables at
the terminals U and V. In factory setting, you have 16 volts and
approx. 5A available on the track.
If you connect a transformer with 3 A (50VA), please also set the
current limitation to 3A. See section 8, page 45 for more information.
Alternatively, you can also supply the LZV200 via a power supply unit.
This is described in section 5.9, p. 41.
Only one kind of power supply may be connected tot he
LZV200. Either a transformer or a power supply unit.
5.2 Track connection: terminals J,K
Only use cables with sufficiently large cross-sections to connect the
tracks and then twist this cable (we recommend 0.25 mm
2
minimum).