To install the NE1032 in an iDataPlex rack, complete the following steps:
1.
Locate, record, and retain the product switch information in order to configure and
register your product. See
“Before Installing the NE1032” on page 32
.
Note:
If this switch is a replacement switch, copy the product information from the
original switch onto the RID label that is shipped with replacement switch and
affix the new label to the bottom of the new switch.
2.
Attach front mounting brackets (Item 1) and rear mounting brackets (Item 6) to
each side of the switch with M4 screws (Item 2). Torque the screws to
approximately 2 newton-meters (Nm) +/- 0.1 Nm (17.7 inch-pounds).
3.
From the front, slide the switch into the rack at the desired height.
4.
Secure the switch to the front rack posts with M6 screws (Item 3), and clip nuts
(Item 4). Torque the screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).