Power LEDs
On the front of the switch, the Power LED on the management panel indicates the
general status of the power supplies. The LED flashes when only one power cord is
connected, and is steady when both power cords are connected (see
).
Additional LED indicators are located on the rear panel of the switch, on the
individual power supply modules. The following table describes the power supply
module LED behavior.
Table 6.
Power supply module status LED behavior
LED
State
Functional Meaning
Power
Off
No AC power is present.
Blink Green
Power supply has AC power and is in standby mode.
Solid Green
Power supply is on and operational.
Blink Amber
Power supply warning event (continuing operation): high
temperature, high power, high current, or slow power
supply fan.
Solid Amber
Power supply shutdown from critical event: power supply
failure, over-voltage, over-current, over-temperature,
power supply fan failure, AC cord unplugged.