Figure 90. PCIe riser-card assembly installation
Step 3. Reconnect all the cables disconnected previously.
After installing the PCIe riser-card assembly, complete the following steps:
1. Reinstall the top cover (see
“Install the top cover” on page 134
2. Reconnect the power cords and any cables that you removed.
3. Install the server in the rack.
4. Power on the server and any peripheral devices.
Remove an adapter
Use this procedure to remove an adapter.
Follow the following instructions accordingly to the location where the adapter has been installed.
Remove an adapter from the system board
Before removing an adapter from the system board:
1. Read the safety information and installation guidelines (see
).
2. Turn off the server and peripheral devices and disconnect the power cords and all external cables (see
“Power off the server” on page 11
).
3. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top
cover, or remove the server from the rack.
4.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=
PLYV5R7hVcs-B2y7oAb54mfyuLrIusa_qE
.
5. Remove the top cover (see
“Remove the top cover” on page 133
).
To remove an adapter from the system board, complete the following steps:
Step 1. Disconnect any cables (including external ones) from the adapter.
Step 2. Open the retention latch.
.
Hardware replacement procedures
91
Summary of Contents for 7D2F
Page 1: ...ThinkSystem SR850P Maintenance Manual Machine Types 7D2F 7D2G and 7D2H ...
Page 8: ...vi ThinkSystem SR850P Maintenance Manual ...
Page 20: ...12 ThinkSystem SR850P Maintenance Manual ...
Page 172: ...164 ThinkSystem SR850P Maintenance Manual ...
Page 176: ...168 ThinkSystem SR850P Maintenance Manual ...
Page 186: ...178 ThinkSystem SR850P Maintenance Manual ...
Page 187: ......
Page 188: ...Part Number SP47A58972 Printed in China 1P P N SP47A58972 1PSP47A58972 ...