Physical and environmental specifications
Dimensions and weight:
Height: 173 mm (6.8 in.)
Width: 482 mm (19.0 in.)
Depth: 804 mm (31.6 in)
Depth with cable management brackets installed: 836 mm (32.9”)
Depth with Full-length I/O Book installed: 921 mm (36.2 in)
Weight:
Minimum configuration: 35.9 kg (79.2 lb)
Typical configuration: 46.4 kg (102.3 lb)
Maximum configuration: 54.7 kg (120 lb)
Supported environment:
The server is designed to the ASHRAE Class A3 guidelines
Air temperature:
Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 - 3,050 m (10,000 ft).
Server off: 5 °C to 45 °C (41 °F to 113 °F); altitude: 0 - 3,050 m (10,000 ft).
Shipment: -40 °C to 60 °C (-40 °F to 140 °F)
Humidity:
Server on: 8% - 85%, maximum dew point 24 °C
Server off: 8% - 85%, maximum dew point 27 °C
Electrical:
Models with 1400 W AC power supplies:
100 -127 (nominal) V AC; 50 Hz or 60 Hz; 10 A (900 W DC output)
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 8 A (1400 W DC output)
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
Maximum configuration: 3.2 kVA
Models with 900 W AC power supplies:
100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 10.7 A
200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 5.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
Maximum configuration: 2.0 kVA
Models with 750 W DC power supplies:
-40 to -75 (nominal) V DC
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.16 kVA
Maximum configuration: 1.7 kVA
BTU output:
Minimum configuration: 546 Btu/hr (160 watts)
Maximum configuration: 10,912 Btu/hr (3,200 watts)
Noise level:
6.6 bels (operating)
6.4 bels (idle)
Lenovo System x3850 X6 (6241)
47