4.2 Mounting
MiniCODER
4.2.1 Cleaning
mounting
surfaces
GEL 244x: Thoroughly clean the mounting surfaces on the machine and on the
MiniCODER as well as the mounting screws to obtain good electrical conductivity.
Ensure the measuring scale and space where the device is installed are free of
contamination and chips from machining.
4.2.2 Mounting
GEL 244x
►
MiniCODER with screen connection cable:
The screen connection cable can be mounted separately (1, recommended)
or at the sensor (2):
2
1
If the cable is used for earthing at the sensor, shorten it to 35 to 40 mm, fit a
cable lug to it and in the next step clamp it under the fastening screw instead
of the washer.
►
MiniCODER with screen plate:
Fit the screen plate to the MiniCODER.
►
Fit 2 screws M4 with spring washers and washers in the slots on the flange.
►
Place the distance gauge in the space where the device is to be installed on
the target wheel.