XC17 - 2 to 5 Ton Air Conditioner / Page 37
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-042-230
TXV
40,000
16.00
13.00
CH33-48
SL280UH090V60C
3946955
XC17-042-230
TXV
40,000
16.00
13.00
CH33-48
SL280UH090XV60C
4235506
XC17-042-230
TXV
40,000
16.00
13.00
CH33-48
SL280UH110V60C
3946956
XC17-042-230
TXV
40,000
16.00
13.00
CH33-48
SL280UH110XV60C
4040549
XC17-042-230
TXV
39,500
15.70
12.70
CH33-48
SLP98UH090V36C
4020869
XC17-042-230
TXV
40,000
15.70
13.00
CH33-48
SLP98UH090V48C
4020870
XC17-042-230
TXV
39,500
16.00
13.00
CH33-48
SLP98UH090V60C
4020871
XC17-042-230
TXV
40,000
15.70
13.00
CH33-48
SLP98UH110V60C
4020872
XC17-042-230
TXV
39,500
14.70
12.20
CH33-48
3844626
XC17-042-230
TXV
40,500
15.70
13.00
CH33-49
G61MPV-36C-090
3844889
XC17-042-230
TXV
40,500
16.00
13.20
CH33-49
G61MPV-60C-090
3844890
XC17-042-230
TXV
40,000
15.70
13.00
CH33-49
G61MPV-60C-091
3844891
XC17-042-230
TXV
40,500
16.00
13.20
CH33-49
G61MPV-60C-110
3844892
XC17-042-230
TXV
40,500
16.00
13.00
CH33-49
G61MPV-60C-111
3844893
XC17-042-230
TXV
40,500
16.20
13.20
CH33-49
SL280UH090V60C
3946957
XC17-042-230
TXV
40,500
16.20
13.20
CH33-49
SL280UH090XV60C
4235507
XC17-042-230
TXV
40,500
16.00
13.00
CH33-49
SL280UH110V60C
3946958
XC17-042-230
TXV
40,500
16.00
13.00
CH33-49
SL280UH110XV60C
4040558
XC17-042-230
TXV
40,500
15.70
13.00
CH33-49
SLP98UH090V36C
4020873
XC17-042-230
TXV
40,500
16.00
13.20
CH33-49
SLP98UH090V48C
4020874
XC17-042-230
TXV
40,000
16.00
13.20
CH33-49
SLP98UH090V60C
4020875
XC17-042-230
TXV
40,500
16.00
13.20
CH33-49
SLP98UH110V60C
4020876
XC17-042-230
TXV
40,000
15.00
12.20
CH33-49
3844627
XC17-042-230
TXV
40,000
15.70
12.70
CH33-50/60C
G61MPV-36C-090
3844899
XC17-042-230
TXV
40,000
16.00
13.00
CH33-50/60C
G61MPV-60C-090
3844900
XC17-042-230
TXV
40,000
15.70
13.00
CH33-50/60C
G61MPV-60C-091
3844901
XC17-042-230
TXV
40,500
16.00
13.20
CH33-50/60C
G61MPV-60C-110
3844902
XC17-042-230
TXV
40,500
16.00
13.00
CH33-50/60C
G61MPV-60C-111
3844903
XC17-042-230
TXV
40,500
16.00
13.20
CH33-50/60C
SL280UH090V60C
3946959
XC17-042-230
TXV
40,500
16.00
13.20
CH33-50/60C
SL280UH090XV60C
4235516
XC17-042-230
TXV
40,500
15.70
13.00
CH33-50/60C
SL280UH110V60C
3946960
XC17-042-230
TXV
40,500
15.70
13.00
CH33-50/60C
SL280UH110XV60C
4040559
XC17-042-230
TXV
40,000
15.70
13.00
CH33-50/60C
SLP98UH090V36C
4020877
XC17-042-230
TXV
40,000
16.00
13.00
CH33-50/60C
SLP98UH090V48C
4020878
XC17-042-230
TXV
40,000
16.00
13.20
CH33-50/60C
SLP98UH090V60C
4020879
XC17-042-230
TXV
40,500
16.00
13.20
CH33-50/60C
SLP98UH110V60C
4020880
XC17-042-230
TXV
40,000
14.70
12.20
CH33-50/60C
3844628
XC17-042-230
TXV
38,000
14.50
12.00
CR33-48
G61MPV-36B-045
3844790
XC17-042-230
TXV
38,500
14.50
12.00
CR33-48
G61MPV-36B-070
3844791
XC17-042-230
TXV
38,000
14.50
12.00
CR33-48
G61MPV-36B-071
3844792
XC17-042-230
TXV
38,500
15.00
12.20
CR33-48
G61MPV-36C-090
3844796
XC17-042-230
TXV
38,500
15.20
12.50
CR33-48
G61MPV-60C-090
3844797
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.