XC17 - 2 to 5 Ton Air Conditioner / Page 28
AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER
EER
Coil or
Air Handler
Furnace
AHRI
Reference
XC17-036-230
TXV
35,600
16.70
14.20
CH33-43B
SL280UH090V36B
3946906
XC17-036-230
TXV
36,000
16.70
14.00
CH33-43B
SL280UH090V48B
3946907
XC17-036-230
TXV
36,000
16.70
14.00
CH33-43B
SL280UH090XV48B
4038762
XC17-036-230
TXV
35,400
15.20
13.00
CH33-43B
3844365
XC17-036-230
TXV
35,200
16.20
13.70
CH33-43C
G61MPV-36C-090
3844565
XC17-036-230
TXV
35,000
15.00
12.70
CH33-43C
3844366
XC17-036-230
TXV
34,800
15.50
13.20
CH33-44/48
G61MPV-36B-045
3844568
XC17-036-230
TXV
34,800
15.70
13.20
CH33-44/48
G61MPV-36B-070
3844569
XC17-036-230
TXV
34,800
15.50
13.20
CH33-44/48
G61MPV-36B-071
3844571
XC17-036-230
TXV
35,000
16.50
14.00
CH33-44/48
SL280UH090V36B
3946908
XC17-036-230
TXV
35,200
16.20
13.70
CH33-44/48
SL280UH090V48B
3946909
XC17-036-230
TXV
35,200
16.20
13.70
CH33-44/48
SL280UH090XV48B
4038723
XC17-036-230
TXV
35,000
15.70
13.50
CH33-44/48
SLP98UH070V36B
4020817
XC17-036-230
TXV
34,600
15.00
12.70
CH33-44/48
3844367
XC17-036-230
TXV
34,800
15.00
12.70
CH33-48
3844368
XC17-036-230
TXV
35,800
16.70
14.20
CH33-49
G61MPV-36C-090
3844574
XC17-036-230
TXV
36,200
17.00
14.20
CH33-49
SL280UH090V60C
3946910
XC17-036-230
TXV
36,200
17.00
14.20
CH33-49
SL280UH090XV60C
4235499
XC17-036-230
TXV
36,000
16.70
14.00
CH33-49
SL280UH110V60C
3946911
XC17-036-230
TXV
36,000
16.70
14.00
CH33-49
SL280UH110XV60C
4040538
XC17-036-230
TXV
35,800
16.70
14.20
CH33-49
SLP98UH090V36C
4020818
XC17-036-230
TXV
35,200
15.20
13.00
CH33-49
3844369
XC17-036-230
TXV
35,600
16.70
14.00
CH33-50/60C
G61MPV-36C-090
3844578
XC17-036-230
TXV
36,200
17.00
14.20
CH33-50/60C
SL280UH090V60C
3946912
XC17-036-230
TXV
36,200
17.00
14.20
CH33-50/60C
SL280UH090XV60C
4235500
XC17-036-230
TXV
36,000
16.70
14.00
CH33-50/60C
SL280UH110V60C
3946913
XC17-036-230
TXV
36,000
16.70
14.00
CH33-50/60C
SL280UH110XV60C
4040539
XC17-036-230
TXV
35,800
16.70
14.20
CH33-50/60C
SLP98UH090V36C
4020819
XC17-036-230
TXV
35,600
16.70
14.20
CH33-50/60C
SLP98UH090V48C
4020820
XC17-036-230
TXV
35,000
15.00
12.70
CH33-50/60C
3844370
XC17-036-230
TXV
34,000
15.20
13.00
CR33-30/36
G61MPV-36B-045
3844508
XC17-036-230
TXV
34,000
15.20
13.00
CR33-30/36
G61MPV-36B-070
3844509
XC17-036-230
TXV
34,000
15.20
13.00
CR33-30/36
G61MPV-36B-071
3844511
XC17-036-230
TXV
34,200
15.70
13.50
CR33-30/36
G61MPV-36C-090
3844512
XC17-036-230
TXV
34,600
15.70
13.50
CR33-30/36
G61MPV-60C-090
3844514
XC17-036-230
TXV
34,600
16.00
13.50
CR33-30/36
G61MPV-60C-110
3844516
XC17-036-230
TXV
34,600
15.70
13.20
CR33-30/36
G61MPV-60C-111
3844518
XC17-036-230
TXV
34,000
15.70
13.20
CR33-30/36
SL280DF090V48B
3946891
XC17-036-230
TXV
34,800
16.20
13.70
CR33-30/36
SL280DF090V60C
3946892
XC17-036-230
TXV
34,600
16.20
13.70
CR33-30/36
SL280DF110V60C
3946893
XC17-036-230
TXV
34,000
15.70
13.20
CR33-30/36
SLP98DF070V36B
4185186
XC17-036-230
TXV
34,000
16.00
13.50
CR33-30/36
SLP98DF090V36C
4185187
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.