5
Figure 18. Secure Wires
Figure 19. Connect White Plug
18. Use the provided plastic wire clamp to secure
the wires between the heater elements and the
breaker panel to the top of the main control board
and terminal strip assembly. Use an additional wire
clamp already in the VVC* control box to secure
the wires. See Figure 18.
Figure 20. Connect Electrical Power
19. Connect the white plug
of the breaker panel to
the white connector of the transformer and
relay assembly. See Figure 19.
20. Follow NEC/CEC and local codes for
the electrical supply. See Figure 19
for power wiring connection location.
NOTE -
Heat kit provides power to indoor unit.
21. Ground power wiring to grounding terminal
installed in step 15.