Page 12
MS8C / MS8H (208-230V)
40-1/8” (1018)
27 (685)
7-7/16”
(189)
1-7/16” (36)
3-1/2”
(90)
2-1/2”
(65)
1-3/4”
(45)
2-9/16”
(65)
2-9/16”
(65)
24 kBtu
22-5/8”
(575)
4”
(102)
4”
(102)
2-9/16”
(65)
1“ (25)
2-9/16”
(65)
1” (25)
30 kBtu
FIGURE 12
INSTALLING WALL SLEEVE
1. Prior to making the hole, check to ensure that neither
studs nor plumbing are directly located behind the hole
location.
CAUTION
Electric Shock Hazard. Can cause injury or death. Avoid
location where electric wiring or conduits may be present
inside the wall.
2. Use either a sabre saw, key hole saw or hole-cutting
drill attachment to cut a 2-3/16-inch (55 mm) diameter
hole in the wall. Hole should be at a slight downward
slant - 3/16” to 3/8” (5 to 10 mm) to the outdoor side.
INSIDE
OUTSIDE
BORING HOLE FOR WALL SLEEVE
FIGURE 13
3. Measure the thickness of the wall from the inside edge
to the outside edge and cut a field-provided PVC pipe