Page 28
TABLE 14
Maximum Allowable Exhaust Vent Lengths With Furnace Installed in a Closet or Basement Using
Ventilated Attic or Crawl Space For Intake Air in Feet
NOTE - Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total
vent length calculation.
Standard Termination at Elevation 0 - 2000 ft
No 90°
Elbows
1-1/2” Pipe
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
Model
030 045 070 090 110 135
030
045
070 090 110 135
030
045
070
090 110 135
030
045
070 090 110 135
1
20
15
10
n/a
n/a n/a
71
56
34
14
n/a
100
100
78
43
n/a
118
117
98
98
60
2
15
10
n/a
66
51
29
9
95
95
73
38
113
112
93
93
55
3
10
n/a
61
46
24
n/a
90
90
68
33
108 107
88
88
50
4
n/a
56
41
19
85
85
63
28
103 102
83
83
45
5
51
36
14
80
80
58
23
98
97
78
78
40
6
46
31
9
75
75
53
18
93
92
73
73
35
7
41
26
n/a
70
70
48
13
88
87
68
68
30
8
36
21
65
65
43
n/a
83
82
63
63
25
9
31
16
60
60
38
78
77
58
58
20
10
26
11
55
55
33
73
72
53
53
15
Standard Termination at Elevation 2001 - 10,000 ft
No 90°
Elbows
2” Pipe
2-1/2” Pipe
3” Pipe
Model
Model
Model
030/045
070
090
110
135
030/045
070
090
110
135 030/045
070
090
110
135
1
71
30
15
n/a
n/a
100
96
53
38
n/a
118
117
98
98
60
2
66
25
10
95
91
48
33
113
112
93
93
55
3
61
20
n/a
90
86
43
28
108
107
88
88
50
4
56
15
85
81
38
23
103
102
83
83
45
5
51
10
80
76
33
18
98
97
78
78
40
6
46
n/a
75
71
28
13
93
92
73
73
35
7
41
70
66
23
n/a
88
87
68
68
30
8
36
65
61
18
83
82
63
63
25
9
31
60
56
13
78
77
58
58
20
10
26
55
51
n/a
73
72
53
53
15