Page 9
B − Compressor (Reciprocating & Scroll)
Make sure all power is disconnected before
beginning electrical service procedures.
DANGER
Some HP29 units utilize a conventional reciprocating
compressor. Table 6 shows the specifications of reciprocating
compressors used in HP29 series units.
Voltage
Unit
Phase LRA RLA Oil fl.oz.
HP29−211
HP29−311
HP29−511
1
1
1
56
96
128
9.8
16.2
17.3
1
49
8.6
3
HP29−651
HP29−653
HP29−653
3
HP29−463
3
37
5.8
460
3
208/230
HP29−653
HP29−461
1
46
7.1
HP29−261
1
75
13.7
HP29−463
123 26.9
HP29−513
3
64
9.0
HP29−513
3
51
7.1
HP29−513
208/230
208/230
208/230
208/230
208/230
208/230
208/230
208/230
460
460
575
HP29 COMPRESSOR SPECIFICATIONS
3
HP29−413
3
87
12.8
460
HP29−413
3
92
54
17.5
1
40
54
4.3
208/230
44
6.4
110 23.4
91
14.0
HP29−411
75
45
10.3
208/230
3
575
45
45
45
45
45
54
54
54
54
54
54
54
54
54
MAN/MODEL
TEC/AV5558F
TEC/AV5558F
TEC/AV5558F
TEC/AV5558F
TEC/AV5545F
TEC/AV5545F
TEC/AV5545F
TEC/AV5545F
TEC/AV5540F
TEC/AV5540F
TEC/AV554OF
COP/CR35K6−TFD
COP/CR35K6−TF5
COP/CR34K6−PFV
COP/CR28K6−PFV
COP/CR22K6−PFV
COP/CR16K6−PFV
HP29−018
1
49
208/230
45
COP/CR16K6−PFV
HP29−024
1
208/230
45
COP/CR22K6−PFV
HP29−042
208/230
3
87
12.8
54
TEC/AV5540F
HP29−042
460
3
44
6.4
54
TEC/AV5540F
HP29−036
3
37.5 5.6
3
75
208/230
460
HP29−036
54
54
TEC/AVD5535EXG
TEC/AVD5535EXT
TABLE 6
7.9
60
10.1
10.3
HP29−211
HP29−261
208/230
208/230
1
1
TEC/AWD5516EXD
48.3
7.9
32
TEC/AWD5522EXD
60
32
10.06
Some HP29 units utilize a scroll compressor. The scroll
compressor design is simple, efficient and requires few
moving parts. A cutaway diagram of the scroll compressor is
shown in figure 8. The scrolls are located in the top of the
compressor can and the motor is located just below. The oil
level is immediately below the motor.
FIGURE 8
SCROLL COMPRESSOR
DISCHARGE
SUCTION
The scroll is a simple compression concept centered around
the unique spiral shape of the scroll and its inherent properties.
Two identical scrolls are mated together forming concentric
spiral shapes. One scroll remains stationary, while the other is
allowed to "orbit." The orbiting scroll does not rotate or turn but
merely orbits the stationary scroll. Due to its efficiency, the
scroll compressor is capable of drawing a much deeper
vacuum than reciprocating compressors. Deep vacuum
operation can cause internal fusite arcing resulting in
damaged internal parts and will result in compressor
failure. Never use a scroll compressor for evacuating or
for deep vacuum operation (operating compressor at 0
psig or lower) on the system. Table 7 shows the
specifications of scroll compressors used in the HP29
series units.
Voltage
Unit
Phase LRA RLA Oil fl.oz.
HP29−030
HP29−060
1
100
16
1
84 14.7
3
3
HP29−048
3
50
7.1
575
3
208/230
HP29−048
1
62
9
HP29−036
HP29−048
HP29−060
HP29−060
HP29−060
208/230
460
208/230
208/230
460
HP29 COMPRESSOR SPECIFICATIONS
3
49.5 7.4
HP29−042
1
120
72
13.5
72
208/230
40
5.8
169 28.8
137 17.3
127
42
20.3
208/230
575
42
42
72
56
72
72
72
MAN/MODEL
COP/ZR61K3−TFE
COP/ZR61K3−TFD
COP/ZR61K3−TF5
COP/ZR61K3−PFV
COP/ZR46K3−TFE
COP/ZR46K3−TFD
COP/ZR46K3−TF5
COP/ZR42KC−PFV
COP/ZR36KC−PFV
COP/ZR30KC−PFV
HP29−048
COP/ZR46K3−PFV
208/230
1
129 23.7
66
3
TABLE 7
Three-Phase Compressor Rotation
Three-phase scroll compressors must be phased
sequentially to ensure correct compressor rotation and
operation. At compressor start-up, a rise in discharge and
drop in suction pressures indicates proper compressor
phasing and operation. If discharge and suction pressures
do not perform normally, follow the steps below to correctly
phase the unit.
1 − Disconnect power to the unit.
2 − Reverse any two field power leads to the unit.
3 − Reapply power to the unit.
Discharge and suction pressures should operate within
their normal start-up ranges.
NOTE − Compressor noise level may be significantly higher
when phasing is incorrect and the unit will not provide
cooling when compressor is operating backwards.
Continued backward operation will cause the compressor
to cycle on internal protector.