background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

6

Front View

Side View

E

F

A

B

C

D

G

H

I

J

K

L

M

SPECIFICATIONS - Model EBVI30

Top View

Figure 2

DIMENSIONS

inches (millimeter)

inches (millimeter)

A

26 1/16” (662 mm)

H

11 1/2” (292 mm)

B

22 3/8” (568 mm)

I

15/16” (24 mm)

C

13 5/8” (346 mm)

J

20 1/8” (511 mm)

D

SM.= 40 1/4”(1022 mm), 

MED. = 45 3/4”(1162 mm), 

LG. = 49 1/4”(1251 mm)

K

15 5/8” (397 mm)

E

SM.= 27 1/2”(699 mm), 

MED.= 30 1/4”(768 mm), 

LG. = .30”(762 mm)

L

**12 3/8” (314 mm)

F

20 7/8” (530 mm)

M

**23 7/16” (595 mm)

G

1   13/16” (46 mm)

SPECIFICATIONS

Natural Gas BTU Input

21,500 to 30,000

Propane Gas BTU Input

22,000 to 28,000

B-Vent Size

4” Dia. Liner

Room Blower CFM

130 cfm

EFFICIENCIES

62 % Nat. Gas; 60 % Prop. Gas

Steady State Effi ciency *

83 % Nat. Gas; 82 % Prop. Gas

NOTES

* The Steady State Effi ciency numbers based on maximum vent confi guration.

** The total glass viewing area equals approx. 290  Sq. In.

*** Due to Lennox' ongoing commitment to quality, all specifi cations, ratings 
and dimensions are subject to change without notice.

Summary of Contents for EVB125

Page 1: ...DONN DANS CETTE NOTICE POURR DUIREAUMINIMUMLERISQUED INCENDIE OUPOUR VITERTOUTDOMMAGEMAT RIEL TOUTE BLESSURE OU LA MORT POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d all...

Page 2: ...ermiculite one propane conversion kits One Warranty Certificate One Fireplace Warning Label One Draft Hood Sliding Tool This gas fireplace heater is a natural con vection heat circulating gas fireplac...

Page 3: ...SUPPLY TO THE APPLIANCE AND HAVE IT SERVICED BY A QUALIFIED PROFES SIONAL AS IT MAY NOT BE OPERATING PROPERLY WARNING CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OFHIGHSURFACETEMPERATURES USE...

Page 4: ...irements Familiarity with these requirements before installation is essential Some important considerationstodiscusswithlocalbuilding officials include 1 Applicablecodes i e UniformMechanical Code Sta...

Page 5: ...5 8 702 mm L 10 7 8 276 mm F 19 3 8 493 mm M 24 7 8 632 mm G 1 15 16 49 mm The total glass viewing area equals approx 270 1 2 Sq In SPECIFICATIONS Natural Gas BTU Input 17 000 to 25 000 Propane Gas BT...

Page 6: ...D 30 1 4 768 mm LG 30 762 mm L 12 3 8 314 mm F 20 7 8 530 mm M 23 7 16 595 mm G 1 13 16 46 mm SPECIFICATIONS Natural Gas BTU Input 21 500 to 30 000 Propane Gas BTU Input 22 000 to 28 000 B Vent Size 4...

Page 7: ...ight Side Wall A G E C B Hearth Protection Side View TopofInsert Mantel Clearance Model EBVI30 The mantel should be located in the shaded area light gray shown below Existing Fireplace Hearth F 15 14...

Page 8: ...pipe Refer to table 7 for suggested sizing of the gas supply line if black iron pipe is being used The gas supply line should be connected to the appliance at step 9 page 12 The gas supply line shoul...

Page 9: ...OR MECHANICAL WEAKNESSES SUCH AS CRACKS LEAKY JOINTS CORRODED OR WARPED SURFACES THE FAULTY POR TION MUST BE REPAIRED OR REPLACED PRIOR TO INSTALLING THIS APPLIANCE Step 3 UNPACK THE INSERT Remove the...

Page 10: ...termiation below the wall or parapet when distance is less than 10 ft as shown below wall or parapet wall or parapet No height above wall or parapet is required when dis tance is greater than 10 ft 7...

Page 11: ...e it forward aligning with guide brackets until the screw hole in the spill tube aligns with the screw hole in the top of the firebox see Figure 12 Secure two parts in place with removed screw While p...

Page 12: ...access door The millivolt control valve has a 3 8 10 mm NPT thread inlet port fitting Make gas line connections All codes require a shut off valve mounted in the supply line Figure 19 illustrates two...

Page 13: ...d fit onto corresponding pins and or log stoppers This will ensure a proper flame and safe combustion 1 Place the rear log onto the 2 corresponding locating pins at the back of the firebox as shown in...

Page 14: ...ont of the forward logs Figure 29 Figure 30 9 Place some vermiculite around the logs as shown in Figure 30 the entire bag of vermiculite will NOT be used Vermiculite Figure 27 7 Install the Top Right...

Page 15: ...donthe surround assembly see Figure 34 or operate the burner with the optional remote control wall thermostat or control switch Control Compartment Access Pull down hinged door to access control compa...

Page 16: ...e the dial down clockwise just past the click the first ON position for the highest speed setting Turning the knob further clockwise will provide slower blower speeds Note If the rheostat is not turne...

Page 17: ...ansparent These weak blue and transparent flames are termed anemic If the air shutter openings are too small sooting may develop IMPORTANT ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURI...

Page 18: ...N 9 1466A SERIAL NUMBER NOMBRE DE SERIE XXX XXX IIIIIIIIIIIIIIIIIIII XXX P N 9 1466A MANTEAU DU DESSUS DE L APPAREIL MAX MAX MODEL NO EBVI25 MANUFACTURED AT Lynwood CA FOR USE WITH NATURAL GAS EQUIPE...

Page 19: ......

Page 20: ...time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for code requirements for your area LHP 1110 West Taft A...

Reviews: