General
This XP13 outdoor heat pump is designed for use with
HFC−410A refrigerant only. This unit must be installed with
an approved indoor air handler or coil. See the Lennox
XP13 Product Specifications bulletin (EHB) for approved
indoor component match ups.
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.
INSTALLATION
INSTRUCTIONS
Elite
®
Series XP13 Units
HEAT PUMP UNITS
506728−01
7/2012
Supersedes 3/2012
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal inju-
ry or loss of life.
Installation and service must be performed by a licensed
professional installer (or equivalent) or service agency.
NOTICE !
For more in−depth information, consult the Installa-
tion and Service Procedures manual, available as
Corp. 0528−L10 on DaveNet or through the Technical
Support department at 800−453−6669.
CAUTION
Before attempting to perform any service or mainte-
nance, turn the electrical power to unit OFF at discon-
nect switch.
STEP 1 −− SETTING THE UNIT −− Clearances
CONTROL PANEL
ACCESS
LOCATION
6 (152)
36 (914)
12 (305)
30 (762)
24 (610)
48 (1219)
MINIMUM CLEARANCE BETWEEN
TWO UNITS
CLEARANCE ON ALL SIDES INCHES (MILLIMETERS)
MINIMUM CLEARANCE
ABOVE UNIT
NOTES:
S
Clearance to one of the other three
sides must be 36 inches (914mm).
S
Clearance to one of the remaining
two sides may be 12 inches
(305mm) and the final side may be
6 inches (152mm).
FIGURE 1