OZONE WARNING

All electronic air cleaners produce a small amount of
ozone.  Some individuals are sensitive to ozone and
may notice an odor or may experience a physiological
response (including lung irritation), especially at high
altitudes or low airflow rates. In such cases, there are
two options available to reduce ozone concentrations:

Option 1 — Cut Jumper: A hairpin-shaped jumper wire
labeled W1, which is located in the power supply (see
Figure 24), can be cut and separated. This will reduce
the maximum operating power and reduce the ozone
generated by as much as 15 percent. It will reduce the
air cleaning efficiency by 5 to 10 percent.

Option 2 — Charcoal Filter: Charcoal filters (available
as an accessory item, see page 15) reduce the ozone
output of the electronic air cleaner without sacrificing
cleaning efficiency. In independent laboratory testing, a

LINE

WHT/BRN

BLK

W1

E3

E2

Cut and separate
Ozone Reduction
Jumper

Cabinet

Pre-Filters

Handle

Contact
Button

Contact
Button

Collecting Cells

1.

Remove existing door from the media air cleaner
cabinet.

2.

Remove existing media cartridge from air cleaner
cabinet.

3.

Remove the two pre-filters from the electronic air
cleaner upgrade kit and insert into cabinet tracks
opposite the air handler (see Fig. 25). These will be
used to catch the larger particles that are in the air
stream before entering the collecting cells.

4.

Insert the two collecting cells into the cabinet behind
the pre-filters. Be sure ionizing wires are directly
behind the pre-filters so the particles can be charged
as soon as the air leaves the pre-filters.

5.

Remove cover plate on the power supply junction box
and remove the knockout needed to bring the wire to
the female receptacle.

6.

Position receptacle with ground in the down position
as shown in Fig. 17 and pull wires through the
receptacle locator on the junction box. Snap the
receptacle into the hole until secure. Connect ground
wire from receptacle and ground wire in kit to cabinet
using rivet and washer as follows:

a) Place washer on rivet
b) Place terminal from ground wire on rivet
c)

Place terminal from receptacle ground wire on
rivet

d) Place rivet in hole in junction box and secure to

cabinet.

Healthy Climate

®

 Electronic Air Cleaner Upgrade Kit

OZONE REDUCTION

Figure 25

7.

For wiring installation (see page 7 and follow all wiring
instructions 7, 8 and 9).

8.

Install the power pack (see page 7 instruction 11).

9.

For operation (see page 8 – Operation).

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, per-
sonal injury or loss of life. Installation and service
must be performed by a qualified installer or service
agency.

!

WARNING

INSTALLATION

Do not operate the blower(s) in the HVAC system
without the door on this unit securely in place. Gas
fumes which could contain carbon monoxide, can be
drawn into the living space resulting in personal
injury or death.

!

WARNING

new charcoal filter was shown to eliminate nearly all of
the ozone generated by the electronic air cleaner. Over
time, however, the charcoal filter becomes less
effective at eliminating ozone. Charcoal filters should be
replaced approximated every six months. Highly
sensitive individuals may elect to replace their charcoal
filters more frequently.

Refer to the Basic Service Guide on page 10 for
additional items which may reduce ozone.

Ozone

Reduction Jumper

Figure 24

Summary of Contents for EAC-14-2

Page 1: ...of the unit serious personal injury or death WARNING Installation of this unit must comply with local electric codes or other applicable codes Review and understand local codes prior to installation...

Page 2: ...system White Dust Lint An electronic air cleaner is designed to collect two major types of contaminants irritants pollens spores molds bacteria etc and black soiling contaminants dirt and smoke partic...

Page 3: ...ch collect the ionized dust dirt and other impurities from the air Each cell must be installed with the ionizing wires on the air entering side Each cell must be oriented with the handles and contact...

Page 4: ...omponent inside the boot For installation of Electronic Air Cleaner Retrofit kit see page 13 If furnace opening cannot be enlarged to required size a sheet metal transition must be used Transition mus...

Page 5: ...er is mounted vertically where return air enters side inlet of furnace OFFSET INSTALLATION Figure 10 Typical use of duct offset to match air cleaner opening If duct connection to furnace allows less t...

Page 6: ...fitting should be used Figure 3 The cabinet can be attached directly Figure 13 or a starting collar can first be fitted to the air handler inlet A butt or slip joint can be used Securely attach the ca...

Page 7: ...d to prevent wire abrasion Vertical Section Wood Block Tape All Joints Figure 16 Hot Neutral Grounding Conductor Front View Figure 17 Floor Conduit Duct Electronic Air Cleaner Figure 18 Cabinet Pre Fi...

Page 8: ...minutes push ON OFF switch on the power pack to the ON position A moderate amount of arcing or snapping may occur at this time which will indicate that the cell s are still damp If the noise is object...

Page 9: ...Unit Weight 43 lbs 44 lbs 52 lbs Power Consumption 40 Watts Max 40 Watts 40 Watts Electrical Input 120 VAC 60 hz 120 VAC 60 hz 120 VAC 60 hz Electrical Output 1 2 Ma 1 5 Ma 1 7 Ma 6450 VDC nom Max Oz...

Page 10: ...Excessive arcing during 1 Wet collecting cell normal operation A Allow cell s to dry after cleaning before applying power Operating Light may blink 2 Damaged collecting cell s A Remove cell s and insp...

Page 11: ...and a general purpose volt ohm meter For example Simpson 260 or equivalent For test purposes the air flow switch may be wired out of the system This will eliminate the need for air flow across the se...

Page 12: ...he temperature range of 65 to 120 F Operation outside this range is not recommended POWER SUPPLY CHECK OUT PROCEDURE 1 Place collecting cell on a well insulated workbench with the cell contact button...

Page 13: ...5 Remove cover plate on the power supply junction box and remove the knockout needed to bring the wire to the female receptacle 6 Position receptacle with ground in the down position as shown in Fig 1...

Page 14: ...14 1 2 2 3 3 4 5 6 8 Replacement Parts...

Page 15: ...EAC 16 EAC 20 Electronic Air Cleaner 90N80 X1187 90N81 1 Cabinet 69H84 X1188 72H01 2 Pre Filter 69H85 X1189 72H02 3 Collecting Cell 69H86 X1190 72H03 4 Power Pack Assembly 80K62 X1191 80K63 5 Ionizin...

Page 16: ......

Page 17: ...ites et des blessures graves voire un d c s pourraient survenir PI CE No 37 6128D Liste d emballage et d exp dition Le colis 1 de 1 contient 1 Bo tier de l purateur d air lectronique 2 Cellules 1 Modu...

Page 18: ...bact ries etc et 2 les contaminants salissants particules de salet et de fum e Les r sidus qui s accumulent sur les plaques d un purateur lectroni que sont noirs toute cette salet est retir e de l ai...

Page 19: ...poussi re la salet et toute autre impuret de l air qui a t ionis e Chaque cellule doit tre install e avec les fils ionisants orient s vers l entr e d air Chaque cellule doit tre orient e pour que les...

Page 20: ...e pl num de sortie d air du g n rateur 4 IMPORTANT Si un humidificateur pulv risation est utilis il doit tre install en aval de l purateur Si le r seau de conduits du g n rateur comporte d j un bo tie...

Page 21: ...la reprised airp n tredanslaprise d air lat rale du g n rateur INSTALLATION COUD E figure 10 Exemple typique de l utilisation d un coude pour adapter le conduit l ouverture de l purateur Si le raccord...

Page 22: ...l sur la prise d air du g n rateur par un assemblage en bout ou coulissant Fixer le bo tier solidement la prise d air du g n rateur en faisant appel au moins deux trous de montage de part et d autre d...

Page 23: ...nchons de caoutchouc sont pr sents pour pr venir l usure des fils Section verticale Bloc de bois Calfeutrer tous les joints Figure 16 Sous tension Neutre Conducteur de MALT Vue de face Figure 17 Planc...

Page 24: ...n la position de marche ON ce stade il est possible qu il y ait beaucoup de claquement et d arcs lectriques Cela signifie que les cellules sont encore humides Si le bruit d range teindre l appareil et...

Page 25: ...10 lb 4 5 kg 10 lb Poids de l appareil 19 5 kg 43 lb 20 0 kg 44 lb 23 6 kg 52 lb Puissance absorb e 40 watts maxi 40 watts 40 watts Courant absorb 120 V C A 60 Hz 120 V C A 60 Hz 120 V C A 60 Hz Cour...

Page 26: ...du manchon noir qui entoure le petit l ment d tecteur B S assurer que le petit l ment d tecteur est bien centr dans le manchon 2 D tecteur de d bit d air laiss hors circuit apr s une r vision 3 Panne...

Page 27: ...n doit le remplacer par un bloc enfichable complet Tension absorb e 120 V C A 60 Hz Sortie du voyant 1 5 2 5 V C C Sortie HT 6450 V C C nom Caract ristiques techniques des cellules collectrices Caract...

Page 28: ...te de 18 49 C 65 120 F Il n est pas recommand de l utiliser une temp rature inf rieure ou sup rieure PROC DURE DE R VISION DU BLOC D ALIMENTATION 1 Placer sur un tabli bien isol la cellule collectrice...

Page 29: ...asser la page 8 Exploitation Des dommages mat riels ainsi que des blessures ou m me la perte de vies peuvent survenir si l appareil est install ajust modifi r vis ou entretenu incorrectement Toute ins...

Page 30: ...14 1 2 3 4 5 5 6 2 3 4 8 5 8 5 6 13 10 11 12 15 Pi ces de rechange...

Page 31: ...14 EAC 16 EAC 20 purateur d air lectronique 90N80 X1187 90N81 1 Bo tier 69H84 X1188 72H01 2 Pr filtre 69H85 X1189 72H02 3 Cellule collectrice 69H86 X1190 72H03 4 Module d alimentation 80K62 X1191 80K6...

Page 32: ......

Reviews: