A - 66
A
LW 320 E MC / LW 400 E MC
Version: 16.03.2015
M A I N T E N A N C E A N D S E R V I C E
Adjust pressure maintaining valve
• Vent filling valve and close afterwards (filling pressure gauge 0 bar)
• Start the compressor
• Observe filling pressure gauge
• When the opening pressure of the pressure maintaining valve is reached, the indicated filling
pressure increases within some seconds from 0 bar up to the adjusted opening pressure.
If the opening pressure does not reach a value between 150 and 180 bar, adjust the pressure
maintaining valve as follows:
Increase opening pressure:
• Vent filling valve (filling pressure 0 bar)
• Loosen clamp screw on the side
• Turn adjusting screw clockwise by using a suitable slotted screwdriver
• Start compressor and check opening pressure, adjust if necessary
• Tighten clamp screw on the side
• Check opening pressure again
Reduce opening pressure:
• Vent filling valve (filling pressure 0 bar)
• Loosen clamp screw on the side
• Turn adjusting screw anti-clockwise by using a suitable slotted screwdriver
• Start compressor and check opening pressure, adjust if necessary
• Tighten clamp screw on the side
• Check opening pressure again
Note
If the adjusted opening pressure of the pressure maintaining valve is higher than the final
pressure of the compressor, the final pressure safety valve blows off before pressure
maintaining valve opens (final pressure = 0 bar). When valve settings are not clear (e.g.
after disassembly / repair), start the adjustment with a low basic setting (turn adjusting
bolt 3 full turns in).
i
Summary of Contents for LW 320 E MC
Page 3: ...A Operating Instructions Breathing Air Compressor LW 320 E MC LW 400 E MC Version 03 15 E...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 71: ...A M A I N T E N A N C E R E C O R D S...
Page 79: ...B Operating Instructions ECC Electronic compressor control www uebler net Version 11 12 E...
Page 99: ...C ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS...
Page 101: ...Inhaltsverzeichnis Table of Contents Sicherheitsventil Safety Valve 60...
Page 161: ...D O P T I O N S...
Page 163: ...C A D D I T I O N A L F I L L I N G H O S E D 2 LW 320 400 E MC...
Page 165: ...C Version 03 02 2015 A D D I T I O N A L F I L L I N G H O S E D 4 LW 320 400 E MC...
Page 166: ...D A U T O M A T I C C O N D E N S AT I O N D R A I N D 5 LW 320 400 E MC...
Page 184: ...D A U T O S H U T D O W N D 23 LW 320 400 E MC...
Page 188: ...D A U T O S T A R T F U N C T I O N D 27 LW 320 400 E MC...
Page 194: ...D Version 03 02 2015 A U T O S T A R T F U N C T I O N Holder Switch box D 33 LW 320 400 E MC...
Page 196: ...D I N T E R S TA G E P R E S S U R E G A U G E D 35 LW 320 400 E MC...
Page 201: ...D O I L P R E S S U R E G A U G E D 40 LW 320 400 E MC...
Page 204: ...D O I L P R E S S U R E M O N I T O R I N G D 43 LW 320 400 E MC...
Page 209: ...C S W I T C H O V E R D E V I C E 2 0 0 3 0 0 B A R D 48 LW 320 400 E MC...
Page 217: ...D A I R C O O L E R C O N N E C T I O N K I T D 56 LW 320 400 E MC...