Filter housing
The black mole carbon filter housing is installed on the right
hand side of the motor.
Inside the filter housing a jet blows air on to the housing wall.
Condensation water and oil are led by centrifugal force to the
bottom of the housing. Air flows through the mole carbon filter
cartridge, which purifies the air from residual moisture and
odours.
Filter cartridge
The high-pressure compressor is equipped with an integrated breathing air purification system. Air
is compressed up to 350 bar, dried and odour- and tasteless purified. Oil residues are bounded.
The breathing air filter cartridge consists of a molecular sieve and activated-carbon filter.
All breathing air filter cartridges are factory vacuum sealed.
We recommend unpacking the filter cartridges just before installation. Filter cartridges which are
exposed too long could be saturated with moisture and become unusable.
Maintenance intervals
Filter cartridges should be changed at the following intervals, at +20°C or more often, depending
on humidity and ambient temperature:
Standard life time at 20°C:
• 5.7 (4,5 - CO/CO2) hours for LW 320 E MC
(47 (39,1 - CO/CO2) hours for LW 320 E MC /
option filter housing)
• 37.5 (31,25 - CO/CO2) hours for LW 400 E
Fig - Filter housing
P/N
Model
Filtering
Filter Volume
000644
000002
LW 320 E MC
LW 320 E MC (Option)
DIN EN 12021 (Breathing Air)
0.57ltr
0,54 ltr
002309
001459
LW 320 E MC
LW 320 E MC (Option)
DIN EN 12021 (Breathing Air) incl. CO/CO2
0.57 ltr
0,54 ltr
000002
001459
LW 400 E MC
DIN EN 12021 (Breathing Air)
DIN EN 12021 (Breathing Air) incl. CO/CO2
0,54 ltr
Caution
Do not run the compressor with empty unfilled cartridges.
Only use genuine L&W cartridges.
!
Summary of Contents for LW 320 E MC
Page 3: ...A Operating Instructions Breathing Air Compressor LW 320 E MC LW 400 E MC Version 03 15 E...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 71: ...A M A I N T E N A N C E R E C O R D S...
Page 79: ...B Operating Instructions ECC Electronic compressor control www uebler net Version 11 12 E...
Page 99: ...C ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS...
Page 101: ...Inhaltsverzeichnis Table of Contents Sicherheitsventil Safety Valve 60...
Page 161: ...D O P T I O N S...
Page 163: ...C A D D I T I O N A L F I L L I N G H O S E D 2 LW 320 400 E MC...
Page 165: ...C Version 03 02 2015 A D D I T I O N A L F I L L I N G H O S E D 4 LW 320 400 E MC...
Page 166: ...D A U T O M A T I C C O N D E N S AT I O N D R A I N D 5 LW 320 400 E MC...
Page 184: ...D A U T O S H U T D O W N D 23 LW 320 400 E MC...
Page 188: ...D A U T O S T A R T F U N C T I O N D 27 LW 320 400 E MC...
Page 194: ...D Version 03 02 2015 A U T O S T A R T F U N C T I O N Holder Switch box D 33 LW 320 400 E MC...
Page 196: ...D I N T E R S TA G E P R E S S U R E G A U G E D 35 LW 320 400 E MC...
Page 201: ...D O I L P R E S S U R E G A U G E D 40 LW 320 400 E MC...
Page 204: ...D O I L P R E S S U R E M O N I T O R I N G D 43 LW 320 400 E MC...
Page 209: ...C S W I T C H O V E R D E V I C E 2 0 0 3 0 0 B A R D 48 LW 320 400 E MC...
Page 217: ...D A I R C O O L E R C O N N E C T I O N K I T D 56 LW 320 400 E MC...