LW 150 ES / LW 200 ES
Version: 31.01.22-001 E
Page A - 21
A
I N S T A L L A T I O N
Fig. Ventilation through facade
Fig. Ventilation via ventilation stack
Ventilation
• Make sure that the compressor always has a sufficient amount of fresh air available for cooling.
• To prevent serious damage, ensure that the cooling air flow can flow freely.
• The necessary cooling air flow can be calculated by using the following formula:
300 x drive power [kW] = required cooling air flow [m³/h]
Example 11kW motor: 300 x 11kW = 3300 m³/h = required cooling air flow.
• The fan capacity for fresh air and warm air must meet at least the required cooling air flow.
The fans must have the same capacity.
Summary of Contents for LW 150 ES
Page 3: ...A Operating Instructions Breathing Air Compressor LW 150 ES LW 200 ES Version 31 01 2022...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...C ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS...
Page 77: ...Inhaltsverzeichnis Kondensat Sammelbeh lter Condensate Catch Tank 46...
Page 125: ...D O P T I O N S...
Page 127: ...D A U T O S T A R T F U N C T I O N D 1 LW 150 200 ES...
Page 132: ...C A D D I T I O N A L F I L L I N G H O S E D 6 LW 150 200 ES...
Page 134: ...C Version 10 09 2021 A D D I T I O N A L F I L L I N G H O S E D 8 LW 150 200 ES...
Page 139: ...D I N T E R S TA G E P R E S S U R E G A U G E D 13 LW 150 200 ES...
Page 143: ...D O I L P U M P D 17 LW 150 200 ES...
Page 146: ...D Version 10 09 2021 Detailed View O I L P U M P D 20 LW 150 200 ES...
Page 147: ...D O I L P R E S S U R E G A U G E D 21 LW 150 200 ES...
Page 150: ...D O I L P R E S S U R E M O N I T O R I N G D 24 LW 150 200 ES...
Page 154: ...D O I L T E M P E R A T U R E M O N I T O R I N G D 28 LW 150 200 ES...
Page 157: ...D C Y L I N D E R H E A D T E M P E R AT U R E M O N I T O R I N G D 31 LW 150 200 ES...
Page 160: ...D F I N A L F I LT E R S E PA R A T O R 2 3 LT R D 34 LW 150 200 ES...
Page 167: ...C A D D I T I O N A L H I G H P R E S S U R E O U T L E T D 41 LW 150 200 ES...
Page 170: ...D A I R C O O L E R C O N N E C T I O N K I T D 44 LW 150 200 ES...
Page 173: ...E A T T A C H M E N T Version 11 12 E...
Page 177: ...INFORMATIONON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 185: ...ANNEX...