LW 150 ES / LW 200 ES
Version: 31.01.22-001 E
Page A - 18
A
I N S T A L L A T I O N
Installation in closed rooms
For installation in closed rooms, observe the following:
• Install the unit horizontally and level. The floor must be vibration-free and capable of taking the
load of the system weight.
• The compressor room must be clean, dry, dust free and as cool as possible. Avoid direct exposure
to sunlight. If possible, install unit in such a manner that the compressor fan can intake fresh air
from outside. Ensure adequate ventilation and exhaust air opening.
• When locating the compressor in rooms of less than 30 m³ space where natural ventilation is not
ensured or other systems having high radiation are operating in the same room, measures must
be taken to provide artificial ventilation.
• Intake air must be free from noxious gas e.g. smoke, solvent vapours, exhaust fumes etc.
• Observe the specified operating temperature (see "Technical Data")!
•
•
•
•
Approximate value - Diameter of intake hose depending on the length of the intake hose
Danger
No operation in explosion-hazard areas.
The unit is not approved for operation in areas prone to explosion.
!
Hinweis
• Intake air must be free from noxious gas e.g. smoke, solvent vapours and exhaust fu-
mes. We recommend not to use the intake air inside the compressor housing. An
intake hose would be recommendable!
i
Pos.
Length of Intake Hose [m]
Diameter of Intake Hose [mm]
1
≤ 03
Ø 30
2
≤ 10
Ø 80
3
≤ 15
Ø 100
4
≤ 20
Ø 120
Summary of Contents for LW 150 ES
Page 3: ...A Operating Instructions Breathing Air Compressor LW 150 ES LW 200 ES Version 31 01 2022...
Page 12: ...A S A F E T Y P R E C A U T I O N S...
Page 19: ...A I N S TA L L AT I O N...
Page 26: ...A O P E R AT I O N...
Page 34: ...A R E M E D Y I N G FA U LT S...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Page 67: ...A M A I N T E N A N C E R E C O R D S...
Page 75: ...C ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS...
Page 77: ...Inhaltsverzeichnis Kondensat Sammelbeh lter Condensate Catch Tank 46...
Page 125: ...D O P T I O N S...
Page 127: ...D A U T O S T A R T F U N C T I O N D 1 LW 150 200 ES...
Page 132: ...C A D D I T I O N A L F I L L I N G H O S E D 6 LW 150 200 ES...
Page 134: ...C Version 10 09 2021 A D D I T I O N A L F I L L I N G H O S E D 8 LW 150 200 ES...
Page 139: ...D I N T E R S TA G E P R E S S U R E G A U G E D 13 LW 150 200 ES...
Page 143: ...D O I L P U M P D 17 LW 150 200 ES...
Page 146: ...D Version 10 09 2021 Detailed View O I L P U M P D 20 LW 150 200 ES...
Page 147: ...D O I L P R E S S U R E G A U G E D 21 LW 150 200 ES...
Page 150: ...D O I L P R E S S U R E M O N I T O R I N G D 24 LW 150 200 ES...
Page 154: ...D O I L T E M P E R A T U R E M O N I T O R I N G D 28 LW 150 200 ES...
Page 157: ...D C Y L I N D E R H E A D T E M P E R AT U R E M O N I T O R I N G D 31 LW 150 200 ES...
Page 160: ...D F I N A L F I LT E R S E PA R A T O R 2 3 LT R D 34 LW 150 200 ES...
Page 167: ...C A D D I T I O N A L H I G H P R E S S U R E O U T L E T D 41 LW 150 200 ES...
Page 170: ...D A I R C O O L E R C O N N E C T I O N K I T D 44 LW 150 200 ES...
Page 173: ...E A T T A C H M E N T Version 11 12 E...
Page 177: ...INFORMATIONON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Page 185: ...ANNEX...