Installation manual - English
Storm braces
Storm braces must be attached to the log
ends with the supplied bolts. It is important
for the log ends to be drilled through in
advance. Please keep the distances
indicated in the drawing so that no
problems occur due to wood swelling or
diminishing.
ADVICE
: Do not turn the bolts tightly so
wood can further swell or diminish.
With the pavilion having settled, you
should adjust the attachments so the wall
logs can settle.
General advice:
Problem:
Gaps appear between the wall logs
Cause:
Additional details are attached to the pavilion that do not allow wood to
swell/diminish.
Solutions:
If the door/window is attached to the wall logs with screws/nails, remove these screws/nails;
If the storm brace is screwed on too tightly, loosen its attachment;
If (rain water) pipes are installed on the wall, loosen their attachments;
Problem:
The doors and windows become stuck.
Cause:
The pavilion/foundation has settled.
Solution:
Check whether the pavilion is level. Level the foundation joists and walls.
Cause:
The doors and windows have swelled due to moisture.
Solution:
Adjust the door and window hinges; if necessary, plane the door or window narrower.
We wish you total success with the pavilion installation and much joy
with this pavilion for many years to come!
Summary of Contents for Palmako Hanna
Page 2: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ...Pavilion Y44 5742 13 19 ...
Page 36: ...Pavilion Y44 5742 15 19 ...
Page 37: ...Pavilion Y44 5742 16 19 ...
Page 38: ...Pavilion Y44 5742 17 19 ...
Page 39: ...Pavilion Y44 5742 18 19 ...
Page 40: ...Pavilion Y44 5742 19 19 ...
Page 41: ......