Page 9/15
28October2022/Version 7
LEM reserves the right to carry out modifications on its transducers,
in order to improve them.
LEM International SA
Route du Nant-d’Avril, 152
1217 Meyrin
www.lem.com
ITZ 5000-S FLEX ULTRASTAB
Back panel
Reference
Description
1
IEC power inlet: This connector accepts a standard IEC power cord (supplied)
2
Type / Serial number plate. Three individual S/Ns may be listed here: One for the ITZ electronics, one for
the matching head and one (optional) for the installed voltage output module
3
Transducer head: Connection to the transducer head
4
Analog out: Output connection to a DMM or other equipment, 15-pin D-Sub female UNC 4-40 screw lock
5
Current ±: Secondary current output
6
Monitor: Voltage output with a buffered replica of the secondary current
7
Status/Interlock signal outputs, 9-pin D-Sub male UNC 4-40 screw lock
8
Option A+B: These positions are for future expansion or customization (not used)
2
8
3
1
7
6
5
4
LEM International SA
Route du
Nant-d’Avril, 152
1217 Meyrin
LEM International SA
Route du
Nant-d’Avril, 152
1217 Meyrin
92.47.08.233.0_03
Labelling
ITZ Ultrastab
TYPE: ITZ Ultrastab
HEAD S/N:
VOM S/N:
UNIT S/N:
Unplug mains cable
before removing cover
MAINS INPUT
100-240VAC
50/60 HZ
300W (MAX)
OPTION A
OPTION B
TRANSDUCER
HEAD
ANALOG OUT
+ CURRENT -
MONITOR
STATUS
Do not apply current to
the transducerhead
before MAINS INPUT is
ON
Do not connect or
disconect the
transducerhead
while MAINS INPUT is
ON
Refer to cutting drawing 92.31.08.266.0
MARKING
ITZ
1 / 1
92.47.08.233.0
04
A4
1:1
07.26.2022
pia
01
01.06.2020
Add new LEM logo
G1933101
PMo
02
04.20.2020
Change LEM Switzerland SA in LEM International SA
G2011101
PMo
03
06.06.2022
Add UKCA and DANGER LOGO, and LEM address
G2204218
pia
04
07.26.2022
Adjust UKCA marking position
G2204218
pia