![Leister WELDPLAST S1 Operating Instructions Manual Download Page 36](http://html1.mh-extra.com/html/leister/weldplast-s1/weldplast-s1_operating-instructions-manual_1873934036.webp)
36
Warnings and error messages
• If there is a warning pending, the user can continue to work without restrictions. You can access more detailed
information about the warning in question via the
function display (27)
by selecting «Show Warnings» in the
Settings menu
.
• If an error occurs, the heating is switched off and the drive is no longer released.
Message type Display
Error
code
Error description
Warning
—
Warning symbol
in the
status display (30)
.
The carbon brushes in the drive needs to be replaced.
The drive can continue to be operated for 5 hours after
the warning symbol first appears. After this time, the error
message «
Error No.0400
» appears. From this point, the
drive is no longer released.
Error
0001
Device has overheated.
Allow the device to cool down.
0020
Air heating element is faulty.
Error!
Contact Leister
service center.
0004
Hardware error.
0008
Air thermocouple is faulty.
0010
Plast thermocouple is faulty.
0040
Plast heating element is faulty.
0100
Blower is faulty.
0200
Communication error.
0400
Drive carbon brushes or overheated drive.
Summary of Contents for WELDPLAST S1
Page 9: ...9 Men f hrung Nur im Advanced Mode verf gbar...
Page 28: ...28 Menu navigation Only available in Advanced Mode...
Page 47: ...47 Guidage par menu Disponible uniquement en Advanced Mode Mode avanc...
Page 66: ...66 Guida menu Disponibile solo in modalit avanzata...
Page 85: ...85 Men s Solo disponible en el Advanced Mode modo avanzado...
Page 104: ...104 Menunavigatie Uitsluitend beschikbaar in Geavanceerde modus...