![Leister UNIDRIVE 500 Manual Download Page 14](http://html1.mh-extra.com/html/leister/unidrive-500/unidrive-500_manual_1873914014.webp)
14
The display is subdivided into four areas:
8.2 Display
21
Displays welding speed in m/min or ft/min (drive direc-
tion)
22
Displays welding temperature in °C or °F
23
Displays air volume in %
20
Status display
During operation, the setpoints of the welding parameters (drive in m/min or ft/min, temperature in degrees
Celsius or Fahrenheit), air volume in percent and, if applicable, information notes are displayed.
You can use the
"Confirm" key (18)
to switch between the welding parameters. Use the
Minus/Plus arrow
keys (17)
to adjust the values individually.
Symbol
Designation
Function
"Motor
On/Off (15)
Switches drive on and off
Heating key
On/Off (16)
Switches heating on and off
Blower symbol
No function
Minus / Plus keys (17)
Setting the required setpoint in
increments of 0.1m/min, 10 °C or 5%
"Confirm"
key (18)
Switches between the setpoints to be set