10
8
7
Check the basic setting of the
welding nozzle (8)
.
• Check whether the material to be welded is clean between the overlap and on the upper and lower sides.
• Then check whether the
welding nozzle (8)
, the
drive/pressure roller (7),
and the
pressure belt (9)
are
clean.
• If necessary, position the optionally available welding plate (
Caution
: The device may fall or drop in an uncontrolled manner due to gravity. The securing point is not designed
to withstand the shock-like stress of an abrupt fall.
Contact the manufacturer without hesitation if uncertainties arise during installation or operation.
Power cord and extension cable
• The nominal voltage specified on the device (
) must match the mains voltage.
• The
power cord (1)
must be able to move freely and must not hinder the user or third parties during work
(danger of tripping).
• The extension cable must be authorized for outdoor use and be marked accordingly. Take into account the
necessary minimum cross-section/gauge for extension cables, as required.
Generators for power supply
When using generators as a power supply, please ensure that the generators are grounded and equipped with
residual-current circuit breakers.
When selecting the nominal output of the generators, the formula «1.5 – 2 × nominal output of the semi-automa-
tic hot-air welder» applies.
Welding plate (available as an option)
6.2 Operating readiness
6.3 Positioning the device