![Leister SEAMTEK 900 AT Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/leister/seamtek-900-at/seamtek-900-at_operating-instructions-manual_1873904023.webp)
23
The
touch panel (2)
consists of a high-quality touchscreen display. Any machine settings can be adjusted on the screen.
After starting up, the start screen is shown on the display together with a number of languages to choose from. Select your
language and press the “Start” button.
7.12.1 Mounting and Adjusting the Guide
To fasten a guide, check whether the
welding
nozzle (12)
has been adjusted. Insert the rod
and then clamp the
guide holder (11)
with the
clamping lever. The guide can be moved into the
desired position on the clamping elements. Once
the guide and the
welding nozzle (12)
have been
adjusted, check that the
welding nozzle (12)
does
not touch anything when swiveling in and out.
Different guides are available as accessories.
Ask your distribution partner about the various
options available.
Caution:
First adjust the
welding nozzle (12)
according to Chapter 7.1.1
before the guide is mounted.
8.1 Start screen
8. The Seamtek 900 AT Control Panel
8.2 Home
The screen changes to the Home view. In this view, all welding parameters can be set and peripheral devices such as the air
pump, heating element, and the drive can be switched on.
11
12