7.10
Welding Arm Options (P, S, Q), Arm Replacement
7.10.1 Changing the Arm
7.10.2 Pedestal
Deactivating the Pedestal
Press the
button for the retaining pin (8 B),
which holds together the
threaded rod (8 A)
and
pedestal, to disengage the lock. Then pull the pin
out while fi rmly holding the pedestal. Carefully lay
the pedestal down. Reinsert the retaining pin so
as not to lose it. Now switch to the quickarm or
sidearm.
To bring the pedestal into the welding position,
lift the
pedestal (8)
upward and insert the
retaining pin (8 B)
by pressing the button until
it is positioned correctly.
Caution:
Always hold the
pedestal (8)
when you detach the
retaining pin (8 B)
. Then carefully lay the pedestal down.
If the pedestal falls downward unchecked, it may sustain irreparable damage.
When folding down the pedal, be mindful of a possible crushing risk and do not keep any parts of your body
between the contact surface and pedestal.
To make replacements between the individual arms, please set all settings to “Manual” and “Off ” in advance. The
transport
rollers (9)
are now open and the
welding nozzle (12)
is in the starting position.
Switch off the motor and select the arm in which you are replacing the:
Pedestal (P)
see Chapter 7.8.2 /
Sidearm (S)
see Chapter 7.8.4 /
Quickarm (Q)
see Chapter 7.8.3
Caution:
To select the active arm, the
motor icon (M)
must be switched off . Make sure that the correct arm
is selected to prevent damage to the drive.
Danger of crushing!
When the nozzle is retracted, there is a risk of crushing because of pneumatically mo-
ving parts. Make sure that no part of the body are trapped when changing the arms.