23
CLASSIC, PREMIUM, SYSTEM
Relay output
Max. voltages
AC 250 V, DC 30 V
Max. currents
AC 3 A, DC 3 A
Max. contact resistance
100 m Ohm at DC 6 V / 1 A
Type of contact
SPST - NO
Insulation IEC/EN 60065
AC 2000 V (50 - 60 Hz) 1 min
Technical data for interfaces
Configuration of internal dip switch (only SYSTEM)
Open Loop or Closed Loop
Power setting function
Setting level OFF…100 %;
1% steps
Temperature control function
Setpoint value specification
50 °C…650 °C, 5 °C steps
Setpoint setting
Potentiometer or
interface
Internal potentiometer
Setpoint value OFF…100 % or
50 °C …650 °C
Interface
Setpoint value OFF…100 % or
50 °C …650 °C
SYSTEM
Signal inputs
with reverse polarity protection
and zero offset
Insulation IEC/EN 60747-5-2
AC 1414 V Peak
Voltage input Uc in relation
to GND iso
DC 0 - 10 V
(Ripple < 0.05 V at
5 °C resolution)
(Ripple < 0.1 V at
1 % resolution)
Max. input voltage
DC 12 V
Nominal input resistance
280kOohm
Current input Ic (2 - conductor
technology)
DC 4…20 mA
(Ripple < 0.1 mA at
5 °C resolution)
(Ripple < 0.15 mA at
1 % resolution)
Max. input current
DC 22 mA
Nominal input resistance
160 Ohm
Supply
with reverse polarity protection
without separation of the
signal inputs
Operating voltage Us in relation to
GND iso
DC 15…24 V
Max. operating voltage
DC 25 V
Power consumption
12 mA at DC 24 V