22
Technical data
CLASSIC
PREMIUM
SYSTEM
Detection of heating element and device overheating with alarm output
•
Heat output steplessly adjustable with potentiometer
•
•
Integrated power electronics
•
•
Protection of heating element and device overheating with alarm output
•
•
Integrated temperature controller
•
Interface for temperature or power set point
•
Integrated temperature probe
•
Display showing setpoint and actual values (°C or °F)
•
Type
LHS 15
LHS 21 S LHS 21 L LHS 41 S LHS 41 L LHS 61 S LHS 61 L
Voltage
V~
120 – 230 120 – 230
230
120 – 230
400
3
×
230 –
3
×
480
–
3
×
230 –
3
×
480
–
Frequency
Hz
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
Power
kW
0.55
–
0.77 1.0
–
2.0
3.3
2.0
–
3.6
2.0
–
4.4
4.0
–
9.0
5.0
–
16.0
Min. air volume
l/min.
60
120
240
240
240
360
500
Max. air pressure
(absolute)
Pa
2
×
10
5
2
×
10
5
2
×
10
5
2
×
10
5
2
×
10
5
2
×
10
5
2
×
10
5
Max. temperature °C
650
650
650
650
650
650
650
Max. ambient
temperature
°C
65
65
65
65
65
65
65
Min. inlet air
temperature
°C
0
0
0
0
0
0
0
Max. inlet air
temperature
°C
65
65
65
65
65
65
65
Emission level
L
pA
(dB)
<
70
<
70
<
70
<
70
<
70
<
70
<
70
Weight
kg
0.4
0.5
0.6
0.8
0.9
3.2
3.7
Conformity mark
2
2
2
2
2
2
2
Safety standard
Type of certification
CCA
CCA
CCA
CCA
CCA
CCA
CCA
Protection class I
1
1
Protection class II
4
4
4
4
4
www.mikst.ru - Leister в России.