![Leica Rugby 55 User Manual Download Page 49](http://html1.mh-extra.com/html/leica/rugby-55/rugby-55_user-manual_1873208049.webp)
7-2
Rugby 55
Troubleshooting
Temperature Alert
All three LED’s on, not flashing - The Rugby is in an
environment where it cannot operate without causing
damage to the laser. This could most often be the
result of direct sunlight.
•
Shade the unit.
The Rugby is working,
but not self-leveling
The Rugby must be in automatic mode to self-level.
•
In automatic mode both the X-axis and Y-axis
LED’s will blink green while leveling.
•
In manual mode, one or both of the X-axis and Y-
axis LED’s will be red.
Unit does not turn on
This symptom may be caused by low or dead batteries.
•
Check, change or charge the batteries.
•
If not the batteries, the Rugby must be returned to
an authorized service center for service.
The Rugby’s distance
is reduced
Dirt may be reducing the output of the laser.
•
Clean the windows of the Rugby and the receiver
to improve performance.
•
If not the windows, the Rugby must be returned to
an authorized service center for service.
Alert
Symptom
Possible Causes and Solutions
H.I.
Y
X