![Leica Rugby 55 User Manual Download Page 41](http://html1.mh-extra.com/html/leica/rugby-55/rugby-55_user-manual_1873208041.webp)
6-4
Rugby 55
Accuracy Adjustment
Checking Vertical Accuracy
To check the vertical accuracy of your Rugby laser, place the unit in the
laydown position on a flat, level surface approximately 50-100 ft (15-30 m)
from a wall.
•
Hang a plumb line on the wall.
•
Move the Rugby until the vertical, rotating beam is aligned to the plumb
line.
•
If the rotating beam is not plumb, adjustment is necessary.