Important Information

1

1. 

Important Information

1.1 

Symbols used in the text and their meanings

Warning:

If this danger is not avoided, then this may result in death or serious injury.

Tip:

Gives you tips to simplify your workflow.

Item numbers for numbering illustrations.

 

"Fig. 7 - 

1

"

Numbers in red refer to item numbers in illustrations.

Manufacturer

Order number

Serial number

Date of manufacture

Observe the Instructions for Use.

This product fulfills the requirements of the EU directives.

Symbol for labeling electrical and electronic equipment in accordance with Section 7 

of the German Electrical and Electronic Equipment Act (ElektroG). ElektroG is the law 

on the bringing into circulation, return and environmentally compatible disposal of 

electrical and electronic equipment.
The CSA test mark means that a product has been tested and fulfills the applicable 

safety and/or performance standards, including the relevant standards defined or 

administered by the American National Standards Institute (ANSI), Underwriters 

Laboratories (UL), the Canadian Standards Association (CSA), the National Sanitation 

Foundation International (NSF) and others.

The package contents are fragile and must be handled with care.

The package must be kept in a dry environment.

Maximum of 4 stacked layers

1

Summary of Contents for RM CoolClamp

Page 1: ...lly Cooled Universal Cassette Clamp Instructions for Use English Order No 14 0502 82101 Revision C Always keep this manual with the instrument Read carefully before working with the instrument Version...

Page 2: ......

Page 3: ...l details of the present Instructions for Use are not to be considered warranted characteristics of our products These are determined only by the contract provisions agreed between ourselves and our c...

Page 4: ...ctions 9 4 2 1 Ventilation openings 9 4 2 2 Position of the cable duct 10 4 2 3 Potential pinching areas 10 4 2 4 Power pack with EU UK UL AU and CCC adapters 11 5 Operation 12 5 1 Prerequisite for se...

Page 5: ...ic equipment in accordance with Section 7 of the German Electrical and Electronic Equipment Act ElektroG ElektroG is the law on the bringing into circulation return and environmentally compatible disp...

Page 6: ...indicated on the title page A nameplate indicating the instrument serial number is attached at the back side of the instrument 1 3 Intended use The RM CoolClamp is an electric cooling specimen holder...

Page 7: ...t must not be operated in rooms with danger of explosion The RM CoolClamp must be operated only in the installation orientation and position prescribed for it It must be ensured that no liquids ingres...

Page 8: ...7 5 V DC Additional data for the RM CoolClamp Operating temperature 10 C to 35 C Operating relative humidity 10 to 80 non condensing Transport temperature 29 C to 50 C Storage temperature 5 C to 50 C...

Page 9: ...omes 4 2 General operating instructions 4 2 1 Ventilation openings Warning To prevent injury and damage provision must be made for an unobstructed air supply refer also to the cleaning instructions in...

Page 10: ...p must be routed to prevent possible severing of the cable when operating the microtome For this purpose attach the cable holder to the microtome and then insert the cable into the cable duct Fig 3 1...

Page 11: ...L AU and CCC adapters Fig 5 1 Select the appropriate adapter for the power supply If the provided plugs of the adapter do not fit to your local power supply please use a converting plug to work with o...

Page 12: ...r a microtome that is already configured 1 Remove knife blade holder with base and specimen clamp 2 Bring the specimen head into the rear end position home position 3 Lock the handwheel in place and w...

Page 13: ...d position by turning the handwheel Fig 6 2 and engage the handwheel lock 2 To release the clamping system turn the screw Fig 6 3 counterclockwise using a size 4 Allen key 3 Push the guide Fig 6 5 of...

Page 14: ...correct If the specimen head moves i e it is raised or lowered fine adjustment is necessary Warning Failure to adjust the force balance may result in injury while working see the Safety information P...

Page 15: ...ventilation openings are free before and during use refer to P 9 4 2 1 Ventilation openings No cleaning in the incubator is permitted The RM CoolClamp must not be disassembled for cleaning 6 2 Mainte...

Page 16: ...w LeicaBiosystems com within the product menu This template has to be used for gathering all required data When returning a product a copy of the filled and signed confirmation has to be enclosed or p...

Page 17: ......

Page 18: ...w LeicaBiosystems com Version 1 2 Revision C 11 2019 Leica Biosystems Nussloch GmbH Heidelberger Str 17 19 D 69226 Nussloch Germany Tel 49 0 6224 143 0 Fax 49 0 6224 143 268 Web www LeicaBiosystems co...

Reviews: