Safety Directions
•
If the product has to be permanently mounted in an exposed location, it is advis-
able to provide a lightning conductor system. A suggestion on how to design a
lightning conductor for the product is given below. Always follow the regulations
in force in your country with regard to grounding antennas and masts. These
installations must be carried out by an authorised specialist.
•
To prevent damages due to indirect lightning strikes (voltage spikes) cables, for
example for antenna, power source or modem should be protected with appro-
priate protection elements, like a lightning arrester. These installations must be
carried out by an authorized specialist.
•
If there is a risk of a thunderstorm, or if the equipment is to remain unused and
unattended for a long period, protect your product additionally by unplugging all
systems components and disconnecting all connecting cables and supply cables,
for example, receiver - antenna.
Lightning
conductors
Suggestion for design of a lightning conductor for a GNSS system:
1. On non-metallic structures
Protection by air terminals is recommended. An air terminal is a pointed solid or
tubular rod of conducting material with proper mounting and connection to a
conductor. The position of four air terminals should be uniformly distributed
around the antenna at a distance equal to the height of the air terminal.
The air terminal diameter should be 12 mm for copper or 15 mm for aluminium.
The height of the air terminals should be 25 cm to 50 cm. All air terminals should
Summary of Contents for MOJO RTK
Page 1: ...Leica User Manual Version 1 1 English ...
Page 41: ...System Installation mojoRTK 41 ...
Page 125: ...Normal System Operation mojoRTK 125 ...
Page 131: ...Entertainment Function mojoRTK 131 ...
Page 139: ...Service mojoRTK 139 ...
Page 143: ...Care and Transport mojoRTK 143 ...
Page 191: ...Technical Data mojoRTK 191 ...
Page 207: ...Additional mojoRTK Information mojoRTK 207 ...