Normal System Operation
mojoRTK
121
Configuring NMEA Output, step-by-step
1. Switch on the mojoRTK console and from the Navigation screen press
to
enter the main menu.
2. Use the main dial to select
Settings -> Extended Features -> NMEA settings
.
3. Select
Output Enabled
to turn NMEA output on, and then press
.
4. Select
Baud Rate
to change the RS232 baud rate, and then press
. Use the
main dial to scroll through the list of baud rates. Press
to select a rate or
to cancel.
5. To change the output rate of a sentence select the desired sentence from the
menu, and then press
. Use the main dial to select either
Off
,
1 Hz
,
5 Hz
,
10 Hz
or
20 Hz
. Press
to select a rate or
to cancel.
)
Not all sentences support output rates greater than 1 Hz.