10.
Select
Add another calibration loop
if more runs have to be
added.
Next
and continue with step 4.
OR
Select
Finish the calibration & store the results
to finish the cali-
bration process.
Next
to view the adjustment results.
11.
Select
Finish
to accept the results. No more runs can be added later.
OR
Select
Redo
to decline all measurements and to repeat all calibration
runs.
OR
Back
returns to the previous screen.
IF the results are
THEN
to be stored
If the Use status is set to Yes,
Next
over-
writes the old adjustment errors with the
new ones.
to be determined again
Redo
rejects all new determined adjustment
errors and repeats the whole procedure.
Refer to paragraph "Combined adjustment
5.4
Adjusting the Tilting Axis Error
The tilting axis error is caused by the deviation between the mechanical tilting
axis and the line perpendicular to the vertical axis. This error affects horizontal
angles. To determine this error, it is necessary to point to a target located sig-
nificantly below or above the horizontal plane.
The horizontal collimation error has to be determined before starting this pro-
cedure.
1.
Leica Captivate - Home
:
Settings
\
TS instrument
\
Check & adjust
2.
Check & Adjust
3.
Select the option:
Check & adjust the tilting axis
4.
Next
The following table explains the most common settings.
☞
Determine the horizontal collimation error (c) before starting this
procedure.
1.
Leica Captivate - Home
:
Settings
\
TS instrument
\
Check & adjust
2.
Check & Adjust
Select the option:
Check & adjust the tilting axis
Next step
Description
☞
Access
Determination of tilt-
ing axis error step-by-
step
Check & Adjust
41