CaptiView

From Eye to Insight

Summary of Contents for CaptiView

Page 1: ...MEDICAL DIVISION User Manual 10 746 768 Version 01 CaptiView From Eye to Insight...

Page 2: ...l Division Max Schmidheiny Strasse 201 CH 9435 Heerbrugg Phone 41 71 726 3333 Fax 41 71 726 3334 Legal disclaimer All of the technical data is subject to change without notice The information provided...

Page 3: ...6 5 2 Operating the CaptiView on the control unit of the Leica M530 OH6 OHX 6 6 Settings for CaptiView 10 6 1 Application 1 FL800 10 6 2 Application 2 IGS 11 6 3 Application 3 Common 12 6 4 Applicatio...

Page 4: ...located on the identification label on the CaptiView Enter this data in your user manual and always refer to it when you contact us or the service workshop regarding any questions you may have Model...

Page 5: ...Only use the CaptiView in proper condition Inform your Leica Microsystems representative or Leica Microsystems Schweiz AG Medical Division 9435 Heerbrugg Switzerland immediately if you detect a produc...

Page 6: ...746 768 Version 01 Design and function 3 Design and function 3 1 CaptiView controls 1 Emergency stop switch 3 2 Design and function of the handles for Leica M530 OH6 OHX 1 1 Joystick for menu navigati...

Page 7: ...t sockets 1 to 4 are assigned only with the following connections 1 XGA 3 IGS 2 XGA 2 FL800 3 XGA 1 General input e g Endoscopic camera 4 XGA Out To the CaptiView 4 1 2 Leica OHX LAN NAV USB ADF XGA I...

Page 8: ...IGS workstation Menu scroll down The keys of the handles can be configured separately on the left and right handle The joystick 2 can be configured for the X Y movement of the microscope or for menu c...

Page 9: ...ightness Decreases the brightness of the superimposed data 5 2 3 User settings You can configure the following settings for the user in the user settings Default brightness for image of overlay and no...

Page 10: ...lay Data Image Injection Channel It can be selected in which eye the image shall be injected Left Right Left Right Show Microscope Data Microscope data can be injected The injected data are Working di...

Page 11: ...guidance You do not need to configure any settings on the control unit 5 2 5 Safety function of the CaptiView If because of a malfunction the shutters cannot be controlled or the display switches itse...

Page 12: ...n of the XGA assignment 6 1 Application 1 FL800 FL800 Input To prepare the Leica operating microscope to display the signal of a Leica FL800 system for a specified user in the CaptiView User DIC setti...

Page 13: ...n 2 IGS IGS Input To prepare the Leica operating microscope to display the signal of an IGS system for a specified user in the CaptiView User DIC settings DIC In 1 No device DIC In 2 No device DIC In...

Page 14: ...on Common Input To prepare the Leica operating microscope to display the signal of e g an endoscope for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 No device DIC In 3...

Page 15: ...re the Leica operating microscope to display the signal of an IGS system and or a Leica FL800 for a specified user in the CaptiView User DIC settings DIC In 1 No device DIC In 2 FL800 DIC In 3 IGS Def...

Page 16: ...perating microscope to display the signal of a Leica FL800 and or e g an endoscope for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 FL800 DIC In 3 No device Default DIC...

Page 17: ...signal of an IGS system 1st priority and or e g an endoscope 2nd priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 No device DIC In 3 IGS Default DIC In DIC In...

Page 18: ...microscope to display the signal of an IGS system 2nd priority and or e g an endoscope 1st priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 No device DIC In 3...

Page 19: ...display the signal of a Leica FL800 1st priority an IGS system 2nd priority and or e g an endoscope 3rd priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 FL800...

Page 20: ...display the signal of a Leica FL800 1st priority an IGS system 3rd priority and or e g an endoscope 2nd priority for a specified user in the CaptiView User DIC settings DIC In 1 Common DIC In 2 FL800...

Page 21: ...To disinfect the CaptiView use compounds from the surface disinfectant group based on the following active ingredients aldehydes alcohols quaternary ammonium compounds Due to potential damage to the m...

Page 22: ...t a white balance for the video camera endoscope connected for the overlay X X If the external data source is a video camera carry out a white balance Cause 3 Defective converter The converter process...

Page 23: ...s remain closed Fault remedy X X Check the IGS workstation If the IGS workstation does not function correctly X X Press the switch for manually switching off the display and opening all shutters 18 re...

Page 24: ...ata Weight CaptiView 1 2 kg 9 4 Ambient conditions Transport 40 C to 70 C 40 F to 158 F Storage 10 C to 55 C 14 F to 131 F to 75 relative humidity Mode 10 C to 40 C 50 F to 104 F to 75 relative humidi...

Page 25: ...23 CaptiView Ref 10 746 768 Version 01...

Page 26: ...24 CaptiView Ref 10 746 768 Version 01 Specifications...

Page 27: ...25 CaptiView Ref 10 746 768 Version 01 Specifications...