17
2 Mounting and starting
2.4 Electrical connection
Caution!
Danger of short circuit
Ensure that the cables are routed without tension, kinking and
chafing, and also avoid routing them around sharp edges.
Caution!
Risk of equipment damage
Faulty cables or cables with incorrect dimensions can lead to
malfunctions and damage to the device.
Only use original cables, or ones approved by the manufacturer.
Always fit the transport cover and lock it to protect electrical
connections from damage.
Use only original cables or cables approved by the manufacturer,
otherwise the complete warranty will automatically be invalidated.
Changes to cables undertaken by the customer are taken into account in
the case of repair.
1. Mount support for the control panel in the vehicle cabin.
2. Remove the transport cover
(9)
and connect the data cable
(10)
to the
control panel
(8)
and terminal box
(11)
on the spreader.
3. Connect the battery cable:
Connect connector
(5)
to the negative pole on the battery.
Connect connector
(2)
(with fuse
(7)
) to the positive pole on the battery.