16
_________________________________________________________________________________________
6.2 Controls at ground level
6.2.1 Battery disconnect switch at ground level
Battery disconnect switch connects and
disconnects the circuit from the + line of the
battery. When main current is switched off,
all low voltage functions are cut off, except
for emergency lowering. DO NOT switch off
the main current when the booms are not in
transport position!
The battery charger charges the battery
even if the disconnet switch is switched off.
6.2.2 Controls on the control valve box at ground level
1. Control levers, drive
2. Water level
3. Hour meter
4. Outrigger pressure indicators, red LEDs
5. Boom lifting indicator, and max. support
force 9kN
6. Control levers, outriggers
6.2.3 Emergency lowering buttons at ground level and releasing of slewing
1. Emergency lowering, upper boom
2. Emergency lowering, lower boom
3. Valve, release of slewing
1
2
3
5
4
6
1
2
3