Trimod MCS
U
ser manual
29
MAIN PAGE
DATA DISPLAYED
5 load availability on output
1st line: Operating status of the EPS. If the text alternates "TRIMOD MCS”
and “EPS in stand-by”, the output is disabled
2nd line: Phase L1 - power in kVA or in W compared with the rated power or
current compared with the rated one and relative percentage
3rd line: Phase L2 - power in kVA or in W compared with the rated power or
current compared with the rated one and relative percentage
4th line: Phase L3 - power in kVA or in W compared with the rated power or
current compared with the rated one and relative percentage
6 measurements on output
1st line: Operating status of the EPS. If the text alternates "TRIMOD
MCS” and “EPS in stand-by”, the output is disabled
2nd line: Output L1 phase: Voltage, current and active power
3rd line: Output L2 phase: Voltage, current and active power
4th line: Output L3 phase: Voltage, current and active power
7 output line voltages
1st line: Operating status of the EPS. If the text alternates "TRIMOD
MCS” and “EPS in stand-by”, the output is disabled
2nd line: line voltage between L1 and L2 on output
3rd line: line voltage between L2 and L3 on output
4th line: line voltage between L3 and L1 on output
8 measurement on input
1st line: Operating status of the EPS. If the text alternates "TRIMOD
MCS” and “EPS in stand-by”, the output is disabled
2nd line: Input L1 phase: Voltage, current and active power
3rd line: Input L2 phase: Voltage, current and active power
4th line: Input L3 phase: Voltage, current and active power
9 bypass line voltages
1st line: Operating status of the EPS. If the text alternates "TRIMOD
MCS” and “EPS in stand-by”, the output is disabled
2nd line: Line voltage between L1 and L2 of bypass line
3rd line: Line voltage between L2 and L3 of bypass line
4th line: Line voltage between L3 and L1 of bypass line
10 battery status
1st line: Operating status of the EPS. If the text alternates "TRIMOD MCS” and
“EPS in stand-by”, the output is disabled
2nd line: voltage, charging current (negative value when charging in
progress, positive value when the batteries are powering the
equipment)
3rd line: battery capacity percentage compared with the nominal percentage,
time remaining, total autonomy time
4th line: battery status:
- Battery Stand-by
- Discharging
- Reserve autonomy
- End autonomy
- Charging - ph1 - battery recharging status (current limitation)
- Charging - ph2 - battery recharging status (voltage limitation)
- Charging - maint: Battery recharging in maintenance mode
- Charging - float.: Battery charging in floating mode
- Testing batteries: Battery test in progress
- Equaliz. batteries: Battery equalizing in progress
- BATTERY FAULT: battery voltage less than 100 V
- MaxTime on Battery: End of the maximum set time for battery
mode operation
Charging -maint
Summary of Contents for Trimod MCS 10
Page 1: ...Item LE10960AA 01 19 01 CT Trimod MCS User manual ...
Page 2: ...2 UK ENGLISH 3 Trimod MCS ...
Page 16: ...16 3 3 Models Trimod MCS 3 5 10 Trimod MCS 7 15 3 Technological description ...
Page 17: ...Trimod MCS User manual 17 Trimod MCS 30 Trimod MCS 20 ...
Page 18: ...18 Trimod MCS 40 Trimod MCS 60 Trimod MCS 80 3 Technological description ...
Page 58: ...58 ...
Page 59: ...Trimod MCS User manual 59 ...