background image

TROUBLESHOOTING

Lights do not turn on with motion (LED does flash):

1. Press and release each button to make sure that the correct lights come

on for each relay. If the lights turn on with the button press, verify that the
correct On Mode is selected in DIP switches 5 and 6.

2. Check to see if light level control is enabled: cover the sensor lens with

your hand. If the lights come on, adjust the light level setting.

3. Check all wire connections, in particular, the Load connection.
4. If lights still do not turn on, call 800.223.4185 for technical support.

Lights do not turn on with motion (LED does not flash)

1. Press and release each button to make sure that the correct lights come

on for each relay. If the lights turn on, verify that the Sensitivity is set to
High/SmartSet.

2. Check the wire connections, in particular, the Ground and Line

connections. Verify that connections are tightly secured.

3. If lights still do not go on, call 800.223.4185 for technical support.

ADJUSTMENTS

Sensor Adjustment

The OSR300S is preset to SmartSet mode. It is designed for “Install and Forget”
functionality. If you need to change the settings, follow the directions below.
All major adjustments to the OSR300S must be made with the wall plate
removed. To access the DIP switches, remove the button cap by squeezing the
top sides of the button assembly and pull it gently away from the unit.
When the adjustments are completed, replace the button cap by inserting
its hinges into the LED light bar and then squeeze the top of the button while
pressing it into the unit. Reinstall the cover plate.

Light Level Adjustment

The light level setting only affects the secondary relay. The light level can be
set with the overhead lights on or off. To enable light level control and set the
threshold to match the current ambient light level, press and hold the Relay 2
button for 3 seconds, until you hear a beep. Step away from the sensor. After
25 seconds another short beep sounds, indicating that the threshold level is
set. This threshold is retained, even if power is lost, until it is disabled then
re-programmed in this manner. To disable light level control, press and hold
the Relay 2 button for ten seconds, until a beep tone sounds.

Reset to Default

Press and hold the Relay

1

button for ten seconds to reset the OSR300S to

factory settings. This resets the sensor occupancy history and disables light
level control (the brightest ambient light will not hold the light off).

Summary of Contents for Pass & Seymour OSR300S

Page 1: ...Horsepower Rating each relay 1 6 HP Time Delay Adjustment 5 to 30 minutes Walk Through Mode 3 minutes if no activity after 30 sec Test Mode 15 sec upon initial power up or DIP switch reset PIR Sensit...

Page 2: ...ither Auto On or Manual On In either mode the load can be turned on or off using the ON OFF button Auto On Load turns on and off automatically based on occupancy If the load is turned off manually aut...

Page 3: ...cancels automatically after five minutes or if a fixed time delay is selected To reenable the Test Mode for an additional five minutes change the time delay from any fixed amount to the SmartSet Test...

Page 4: ...wing Fresnel lens with 180 degree field of view Masking the lens Opaque adhesive tape is supplied so that sections of the sensor s view can be masked This allows you to eliminate coverage in unwanted...

Page 5: ...n Wait one minute then push the Auto ON OFF switch for each load and the lights will turn on There is a delay due to initial power up of the sensor that only occurs during installation Screw Terminal...

Page 6: ...N OFF 6 Auto On Manual On Relay 2 ON Mode 4 Use Relay 1 Delay Add 10 minutes Delay Relay 2 Disconnect 1 2 3 4 5 6 7 8 Time Delay FACTORY PRESETS Delay Relay 2 Disconnect ON Relay 1 On Mode Relay 2 On...

Page 7: ...follow the directions below All major adjustments to the OSR300S must be made with the wall plate removed To access the DIP switches remove the button cap by squeezing the top sides of the button asse...

Page 8: ...eturn or repair 2 return the product to Pass Seymour Legrand postage paid with your name and address and a written description of the installation or use of the Pass Seymour Legrand product and the ob...

Reviews: