background image

SmartSet™

Records typical occupancy patterns. Using this history

Time Delays

(which is constantly updated), it chooses an optimal

time delay from two minutes (if the space is usually

vacant) up to 30 minutes (if the space gets heavy

usage). SmartSet behavior starts immediately, and is

refined continually as history is collected.

Fixed Time Delay

DIP switch selections provide fixed time delays of

5, 10, 15, 20 or 30 minutes.

Walk-Through Mode

Use for rooms that have frequent walk-through traffic

(i.e., room that accepts mail deliveries). The OSR300S

turns the load off three minutes after the area is

initially occupied, if no motion is detected after the

first 30 seconds. If motion continues beyond the first

30 seconds, the SmartSet or Fixed time delay applies.

Test Mode

To confirm proper operation of the sensor, a short

Time Delay

initial time delay of 15 seconds is set as the default

(SmartSet/Test) mode. This Test Mode cancels

automatically after five minutes, or if a fixed time

delay is selected. To reenable the Test Mode for an

additional five minutes, change the time delay from

any fixed amount to the SmartSet/Test setting.

Delay Relay 2

Both relays use the same Time Delay, unless DIP

Disconnect

switch #4 is turned on, enabling a delayed disconnect

for relay 2. When the delayed disconnect is enabled,

relay 2 turns off 10 minutes after relay 1 and during

Test Mode, relay 2 turns off 10 seconds after relay 1.

High/SmartSet™

The OSR300S monitors the controlled environment

and automatically selects the maximum sensitivity

setting that will provide reliable operation without

false detection. This setting is constantly updated.

Low

Fixed sensitivity mode, reduces detection range.

Alerts

To warn an occupant that the load is about to be turned off, the OSR300S

provides audible alerts.

Sensitivity Adjustment

Audible Alerts

Sensor "chirps" twice – at one minute and at

30 seconds before turn-off. A distinct alert sounds

10 seconds before the lights go off.

No Alerts

No warning is provided.

Visit our website at www.passandseymour.com

Summary of Contents for Pass & Seymour OSR300S

Page 1: ...Horsepower Rating each relay 1 6 HP Time Delay Adjustment 5 to 30 minutes Walk Through Mode 3 minutes if no activity after 30 sec Test Mode 15 sec upon initial power up or DIP switch reset PIR Sensit...

Page 2: ...ither Auto On or Manual On In either mode the load can be turned on or off using the ON OFF button Auto On Load turns on and off automatically based on occupancy If the load is turned off manually aut...

Page 3: ...cancels automatically after five minutes or if a fixed time delay is selected To reenable the Test Mode for an additional five minutes change the time delay from any fixed amount to the SmartSet Test...

Page 4: ...wing Fresnel lens with 180 degree field of view Masking the lens Opaque adhesive tape is supplied so that sections of the sensor s view can be masked This allows you to eliminate coverage in unwanted...

Page 5: ...n Wait one minute then push the Auto ON OFF switch for each load and the lights will turn on There is a delay due to initial power up of the sensor that only occurs during installation Screw Terminal...

Page 6: ...N OFF 6 Auto On Manual On Relay 2 ON Mode 4 Use Relay 1 Delay Add 10 minutes Delay Relay 2 Disconnect 1 2 3 4 5 6 7 8 Time Delay FACTORY PRESETS Delay Relay 2 Disconnect ON Relay 1 On Mode Relay 2 On...

Page 7: ...follow the directions below All major adjustments to the OSR300S must be made with the wall plate removed To access the DIP switches remove the button cap by squeezing the top sides of the button asse...

Page 8: ...eturn or repair 2 return the product to Pass Seymour Legrand postage paid with your name and address and a written description of the installation or use of the Pass Seymour Legrand product and the ob...

Reviews: