background image

1

2

3

4

5

6

7

8

S

qu

ee

ze

H

er

e

ON/OFF Buttons
Relay 1
Relay 2

DIP Switches

LED

Lens

DIP SWITCH SETTINGS

5

Auto On

Manual On

Relay 1 ON Mode

SmartSet/Test

10 minutes

10 minutes

15 minutes

15 minutes

20 minutes

30 minutes

5 minutes

1 2 3

Time Delay

DIP Switch #s:

=ON

=OFF

6

Auto On

Manual On

Relay 2 ON Mode

4

Use Relay 1 Delay

Add 10 minutes

*

Delay Relay 2 Disconnect

1

2

3

4

5

6

7

8

Time Delay

FACTORY

PRESETS

Delay Relay 2 

Disconnect

ON

Relay 1

On Mode

Relay 2 On Mode

Audible Alerts

Sensitivity

®

®

Walk-Through Mode enabled

Factory Settings

7

Disabled

Enabled

Audible Alerts

DIP Switch #

DIP Switch #

8

High/SmartSet

Low

Sensitivity

DIP Switch #

DIP Switch #

DIP Switch #

®

®

®

*

10 seconds in Test mode

Call 800.223.4185 for Technical Support

Summary of Contents for Pass & Seymour OSR300S

Page 1: ...Horsepower Rating each relay 1 6 HP Time Delay Adjustment 5 to 30 minutes Walk Through Mode 3 minutes if no activity after 30 sec Test Mode 15 sec upon initial power up or DIP switch reset PIR Sensit...

Page 2: ...ither Auto On or Manual On In either mode the load can be turned on or off using the ON OFF button Auto On Load turns on and off automatically based on occupancy If the load is turned off manually aut...

Page 3: ...cancels automatically after five minutes or if a fixed time delay is selected To reenable the Test Mode for an additional five minutes change the time delay from any fixed amount to the SmartSet Test...

Page 4: ...wing Fresnel lens with 180 degree field of view Masking the lens Opaque adhesive tape is supplied so that sections of the sensor s view can be masked This allows you to eliminate coverage in unwanted...

Page 5: ...n Wait one minute then push the Auto ON OFF switch for each load and the lights will turn on There is a delay due to initial power up of the sensor that only occurs during installation Screw Terminal...

Page 6: ...N OFF 6 Auto On Manual On Relay 2 ON Mode 4 Use Relay 1 Delay Add 10 minutes Delay Relay 2 Disconnect 1 2 3 4 5 6 7 8 Time Delay FACTORY PRESETS Delay Relay 2 Disconnect ON Relay 1 On Mode Relay 2 On...

Page 7: ...follow the directions below All major adjustments to the OSR300S must be made with the wall plate removed To access the DIP switches remove the button cap by squeezing the top sides of the button asse...

Page 8: ...eturn or repair 2 return the product to Pass Seymour Legrand postage paid with your name and address and a written description of the installation or use of the Pass Seymour Legrand product and the ob...

Reviews: