31
NOVO Technical Handbook - NE41 15013-02 v2.0
5.7
Examples
In the following sections examples will be given of how to configure NOVO Not all
parameters are shown, only those most relevant for the purpose of each example.
When calling an alarm receiver, the protocol used by NOVO must correspond to the
protocol supported by the alarm receiver.
5.7.1 A simple alarm sequence
The user triggers an
alarm event
by pressing the alarm button on a SMILE registered
in NOVO.
Radio message from SMILE is received by NOVO. This alarm event is by configuration
associated to the alarm type
User alarm from trigger
.
This
alarm type
belongs to an
alarm type group
configured to use
sequence
#1.
Sequence #1
consists of 1
step
.
This step is configured as follows:
Step
Call type
Carrier type
Call attempts
Next step if success
1
A
PSTN
2
Stop
Table 14.
Example of steps in a sequence.
The
Carrier type
determines the carrier used to transmit the alarm.
The
Call attempts
determine how many attempts of this step will be made to transmit
the alarm in case of a failed call attempt.
Next step if success
allows for an action (Step) in case of a successful alarm call. In
this case none will be taken.
The
Call type
(A) consists of several parameters. The parameters used in this
example are the following:
Call type
Address/phone number
Protocol
A
5553232
Homephone
Table 15.
Example of call type parameters.
Note that Call types have many parameters and depending on the protocol different
parameters are required to be set.