When toggling Home/Away/Passive to
Off
the unit will do the following:
• Stop Passive timer and remove any pending or ongoing passive events.
• Remove configuration of
Home alarm type
from
Extra button (B3)
.
• Ensure unit is in Home mode.
6.3 Programming with LPP/HAND
NOVO models with PSTN can be programmed with Local Programming Protocol (LPP)
if they are not configured to communicate with CMP.
To enter LPP during an open PSTN connection, press and hold Reset button (B2)
while pressing Extra button (B3).
The protocol uses DTMF tones to transfer the programming commands. Programming
can be done over the PSTN line or with a HAND unit.
For more information about LPP contact your distributor or NEAT.
Parameter
DTMF Command
HAND Command
Telefphone no A
00#NNN#
[Tel A] NNN [OK]
Telefphone no B
01#NNN#
[Tel B] NNN [OK]
Alarm code
15#NNN#
[CODE] NN [OK]
Protocol
45#NNN#
[PROT] NN [OK]
Set time
84#HHMM#
84 [OK] HHMM [OK]
Exit programming
90##
[END]
Table 25.
LPP programming parameters.
For more information about HAND please refer to HAND User Manual, NE41 07001-02.
.
7
Real Time Clock (RTC)
NOVO is equipped with a real time clock (RTC). The clock runs continuously, even
when the unit is turned off or it is running on the backup accumulator.
The RTC is updated regularly via NTP servers if the unit is connected to the internet.
NOVO supports Daylight Savings Time and this is configurable. Please contact NEAT
or your distributor to verify that your time zone is supported.
8
Alarm and event log
NOVO logs the last alarms and events. If the unit is connected to CMP (Neat
Carephone Management Portal) these alarms and events are synchronized to the
Management Portal. For more information on these logs and/or access to them,
contact your distributor or access the CMP.