17
OCPP
USER GUIDE
WWW.LEGRAND.COM
CORE PROFILE
OCPP 1.6
READ
WRITE
BY DEFAULT
REMARKS
StopTxnAlignedData
Required
OK
Accepted
Please check “supported-
StopTxnAlignedData”
StopTxnAlignedDataMax-
Length
Optional
OK
N.A
10
StopTxnSampledData
Require
OK
Accepted
Please check “supported-
StopTxnSampledData”
StopTxnSampledDataMax-
Length
Optional
OK
N.A
10
SupportedFeatureProfiles
Required
OK
N.A
Core,FirmwareMan-
agement, LocalAuth-
ListManagement,Re-
moteTrigger,Reserva-
tion,SmartCharging
SupportedFeatureProfiles-
MaxLength
Optional
OK
N.A
6
TransactionMessageAt-
tempts
Required
OK
Accepted
3
TransactionMessageRetryIn-
terval
Required
OK
Accepted
10
UnlockConnectorOnEVSide-
Disconnect
Required
OK
Accepted
True
No action on Legrand station
(always true)
WebSocketPingInterval
Required
OK
Accepted
300
No action on Legrand station
SupportedFileTransferProto-
cols
Required
OK
OK
FTP, SFTP, FTPS,
HTTP, HTTPS