8
Battery fault postponement
Operation
If the battery malfunctions, the smoke alarm beeps approx. every 50 secs.
This signal can be postponed temporarily.
Battery fault postponement
1 - Battery fault
indicated:
1 long beep + 1 red
flash approx. every
50 secs.
2 - Press the Test button,
3 short beeps confirm
that the battery fault
has been postponed for
12 hours.
3 - 12 hours later:
1 long beep + 1 red
flash approx. every
50 secs. Battery fault
indicated again.
Decommissioning the self-contained smoke detector/alarm
Temporary or for disposal
1 - Remove the tab from its slot.
2 - Insert the tab between the end of the battery and the metal part.
3 - Press the Test button to check it is switched off.
When disposing of them, take your products to an approved recycling centre.
Usage tips
Audible event identification
Audible signalling
Event meaning
5 quick short beeps
Power-up
1 short beep/1 sec
Smoke level detected close to alarm level
2 short beeps in
succession
Event acknowledgement (exit override mode)
3 short beeps in
succession
Event acknowledgement (activate override mode)
Illuminated event identification
Visual signalling
Event meaning
1 red flash/1 sec
Switch to alarm mode
1 red flash/7 secs
Activation of override mode without any smoke
1 red flash/2 secs
Activation of override mode with smoke present
1 red flash/50 secs
Smoke alarm operating normally
Audible and illuminated event identification
1 red flash + 1 long beep/50 sec: battery fault (main power supply source, see
above instructions)