background image

BS-506/WL

WIRELESS INTERCONNECT 

BATTERY OPERATED 

SMOKE ALARM

IP

20

10

 years

Optical

85dB@3m

EN14604

200

8

EN

300220-2

Battery 

Life

BS-506/WL

10

 years

Replaceable batteries: 2x AA Lithium FR6 (L91)

0.110 dB/m

Optical and Acoustic > 85dB (A) at 3 m

Yes
Yes
Yes

Ceiling

Wireless

Optical

IP20

EN14604-200

8

, EN300220-2

o

0 to 4

5

  C

Up to 93% 

ABS/PC, PC

Ø1

 

mm

30 x 43 

.

185gr.

POWER SUPPLY
BATTERY LIFE

SMOKE CONCENTRATION SENSITIVITY

INDICATORS

ALARM SILENCE FACILITY

LOW BATTERY WARNING
LOW BATTERY SILENCE FACILITY
MOUNTING LOCATION
INTERCONNECTABLE
INTERACTION POSSIBILITY

OPERATIONAL FREQUENCY RANGE

TRANSMIT POWER
TRANSMISSION RANGE

>100m in open area (LoS)

< 13,5 dBm

Up to 40 Smoke alarms

868-870 MHz

DETECTION METHOD
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH

OPERATION TEMPERATURE RANGE

RELATIVE HUMIDITY

CONSTRUCTION MATERIAL

EXTERNAL DIMENSION

WEIGHT
GUARANTEE

Technical Characteristics

3 years (1 year for the batteries)

BS-506/WL

Wireless Interconnect 
Battery Operated Smoke Alarm

EN 

14604:2008

, EN 300220-2

DoP: 921506002_59_001

False alarm is often caused by dust or steam. 
After the batteries replacement, the device performs an auto-adjusting process in 8 hours period to establish its 
operation.  If  false  alarm  happens  within  this  period,  it  is  important  to  clean  the  smoke  alarm  as  described  in 
maintenance paragraph.
If a smoke alarm does not perform the "Remote Device Test", perform a "Factory Reset" and reinstall it on the 
network.  If  it  is  far  from  neighboring  smoke  alarms,  you  may  need  to  install  an  additional  smoke  alarm  in 
between.
If  a  smoke  alarm  receives  a  low signal  level,  place  it  closer  to  its  nearest  smoke  alarm  or  install  a  new smoke 
alarm in between.

Recycling and Desposal

Troubleshooting

The WEEE symbol means that this product and batteries must be disposed separately from other household 

waste. When they reach their end of life, take them to a designated waste collection point in your area to 

guarantee a safe disposal or recycling. Protect the environment, human health and natural resources!

Indications Overview

Overview of Test Key Combinations

Battery and Wireless Signal Strength Tests

1 Red

Per Minute

1

-

-

-

-

-

-

1

1

1

Only on alarm mode

Only on alarm mode

1

1

1

1

2

2

1

1

2

2

3

3

1

3

None

The device operates
normally

1 Red

Per Second

Alarm Pattern

Device Under Testing

1 Red

Per Second

Alarm Pattern

Smoke Detection

1 Red

Per 10 Seconds

None

9 minutes
reduced sensitivity

3 Yellow

Per 43 Seconds

None

Exit from 
alarm function

None

Replace the 
batteries

None

3 short sounds

every minute

Replace the 
smoke alarm

1 short sound

every minute

ALARM

HUSH SMOKE ALARM
(LOCAL)

FUNCTION CHECK

TEST OF ALL SMOKE ALARMS
(REMOTE)

HUSH

HUSH OF ALL SMOKE ALARMS
(REMOTE)

ALARM
MEMORY

BATTERY STATUTS
CHECK

LOW
BATTERY

SIGNAL STRENGTH
TEST

FAULT
WARNING

NETWORK INSTALLATION

(

CENTRAL)

NETWORK INSTALLATION

(

PERIPHERAL)

NORMAL OPERATION

TEST SMOKE ALARM
(LOCAL)

Visual Indication

(flashing)

Short

Press

Modes

Operations

Flashing Number

Audio Signal

Long

Press

Battery Level

Comments

Sum of

Pressings

Comments

Signal Strength

4

5

9215060

02

_0

9

_00

3

9215060

02

_0

9

_00

3

1. Remove the smoke alarm the from mounting plate following Step 1 of the installation instructions.
2. Clean the device as described in maintenance paragraph.

4. Place the smoke alarm on the mounting plate and secure it by turning it clockwise.

3. Replace the old batteries by a new pair. Use recommended batteries for more reliable operation.

5. Test  the  correct  operation  of  your  smoke  alarm  as  described  in  Device  Test  paragraph.  If  no  sound  is 

generated, the smoke alarm must be replaced immediately!

Battery Replacement

1
2
3
4
5

Very Low

Very Weak

Low

Weak

Medium

Medium

High

Strong

Very High

Very Strong

European
manufacturers

Thank you for your trust in our products  

Olympia Electronics - European manufacturer

Olympia Electronics reserves the right to repair or to replace the returned goods 
and to or not

 

charge the buyer depending on the reason of defection. Olympia 

Electronics reserves the right to charge or not the buyer the transportation cost.

Olympia Electronics guarantees the quality, condition and operation of the goods. 
The period of warranty is specified in the official catalogue of Olympia Electronics 
and also in the technical leaflet, which accompanies each product. This warranty 
ceases to exist if the buyer does not follow the technical instructions included in 
official documents given by Olympia Electronics or if the buyer modifies the goods 
provided  or  has  any  repairs  or  re-setting  done  by  a  third  party,  unless  Olympia 
Electronics has fully agreed to them in writing. 

Products that have been damaged 

can be returned to the premises of our company for repair or replacement, as long 
as the warranty period is valid.

Warranty

72

nd

 

km

O

.

N

.

R

Thessaloniki-Katerini

P.C. 60300 P.O. Box 06 Εginio Pierias Greece

www.olympia-electronics.com

[email protected]

EGINIO
PIERIAS
60

300

 

GREECE